Installation
24
Instruction Manual SCE
3
is
3.5
Circuit diagram
shows the electrical diagrams for unvented and vented installations.
These diagrams are used in the paragraphs below in which the actual
connections are described.
G31 (propane)
Nominal load (Upper Value). kW
33.1
41.4
52.8
58.2
78.4
98.3
125.5
136.2
Supply pressure
mbar
37
37
37
37
37
37
37
37
Burner pressure
(1
mbar
-
-
-
-
-
-
-
-
Gas consumption
(2)
kg/h
2.4
3.0
3.8
4.2
5.6
7.0
9.0
9.7
1.
If using a flat sealing plate or high-low control program, instead of a burner pressure regulator, it is assumed that the burner pressure
is equall to the supply pressure. In practice however the burner pressure will be lower,
2.
Based on 1013.25 mbar and 15°C
Table 3.6
Data general
Description
Unit
SCE
80-1
15
SCE
80-1
40
SCE
80
-
180
SCE
95-
199
SCE
95
-
2
60
SCE
70
-
360
SCE
65-
4
00
SCE
65
-
500
Contents
litres
309
309
298
357
335
278
253
252
Number of bar
burners/injectors
-
3
3
4
4
7
7
9
6
Number of flue tubes/flue
baffles
-
5
5
7
6
9
12
16
17
Empty weight
kg
214
214
227
237
262
262
278
330
Number of anodes
-
2
2
2
2
3
3
4
4
Maximum working pressure bar
8
8
8
8
8
8
8
8
Table 3.5
Information on gas categories, appliance category: II2H3+ (Continued)
Description
Unit
SCE
80-115
SCE
80-140
SCE
80-180
SCE
95-199
SCE
95-260
SCE
70-360
SCE
65-400
SCE
65-500
Table 3.7
Electrical data
DESCRIPTION
Unit
All models
Electrical power consumption
W
30
Supply voltage
Volt
(VAC)
230 (-15% +10%)
Net frequency
Hz
50 (±1 Hz)
Summary of Contents for SCE 65-400
Page 2: ...your installer ...
Page 4: ...4 SCE Instruction Manual ...
Page 8: ...8 Instruction Manual SCE gis ...
Page 12: ...Introduction 12 Instruction Manual SCE 1 gis ...
Page 18: ...Operating the appliance 18 Instruction Manual SCE 2 gis ...
Page 42: ...Installation 42 Instruction Manual SCE 3 is ...
Page 46: ...Filling and draining 46 Instruction Manual SCE 4 gis ...
Page 64: ...Maintenance 64 Instruction Manual SCE 9 s ...