Packaging
Release R.1.0 Uk
21
is
3.2
Packaging
To avoid damaging the appliance, remove the packaging carefully.
It is best to unpack the appliance at or near its intended location.
c
Note
The appliance may only be put down the right way up. Make sure that the
appliance does not get damaged after unpacking it.
3.3
Environmental
conditions
c
Note
The appliance may not be used in rooms where chemical substances are
stored or are used due to the risk of explosion and corrosion of the
appliance. Some propellants, bleaching agents, degreasing agents etc.
disperse explosive vapours and/or vapours, which cause accelerated
corrosion. If the appliance is used in a room in which such substances are
present, the warranty will be void.
SCE-appliances are open appliances and may only be fitted in an open
installation room. They fall under category B11BS.
3.3.1
Working space
For access to the appliance it is recommended that the following distances
are observed (see
):
•
AA: from the appliance's control column and cleaning openings: 100 cm.
•
BB: around the appliance: 50 cm.
•
The top of the appliance (room to replace the anodes):
-
100 cm if using fixed anodes, or
-
50 cm if using flexible anodes.
If the space is smaller than 100 cm you can order flexible magnesium
anodes from State Water Heaters.
n
Remark
When installing the appliance, be aware that any leak from the tank and/or
connections can cause damage to the immediate environment or floors
situated below the appliance. If this is the case the appliance should be
installed with a floor outlet or in a suitable metal leak tray.
A leak tray must have a reliable outlet and must be at least 5 cm deep with
a length and width of a minimum of 5 cm larger than the diameter of the
appliance.
3.3.2
Humidity and ambient temperature
The installation room must be frost-free, or be protected against frost.
indicates the environmental conditions, which must be observed to be able to
guarantee correct operation of the electronics that are used.
Table 3.1
Humidity and ambient temperature specifications
Humidity and ambient temperature
Humidity
max. 93% RH at +25°C
Ambient temperature
Functional: 0
≤
t
≤
60°C
Summary of Contents for SCE 65-400
Page 2: ...your installer ...
Page 4: ...4 SCE Instruction Manual ...
Page 8: ...8 Instruction Manual SCE gis ...
Page 12: ...Introduction 12 Instruction Manual SCE 1 gis ...
Page 18: ...Operating the appliance 18 Instruction Manual SCE 2 gis ...
Page 42: ...Installation 42 Instruction Manual SCE 3 is ...
Page 46: ...Filling and draining 46 Instruction Manual SCE 4 gis ...
Page 64: ...Maintenance 64 Instruction Manual SCE 9 s ...