- 34 -
MU0091.B
10.4 Corrective maintenance
10.4
Maintenance corrective
EN
Problem
Possible cause
Corrective action
Winch won’t operate in
either direction or motor
doesn’t operate
Power
is
not
connected
-or-
Emergency on/off
switch is in “off”
position
A) Check wiring connections. Check for 12 at
positive (+) terminal on controller. Check for
voltage at blue and yellow terminals with remote
switch in either direction.
B) Check position of emergency on/off switch.
Power to remote
pendant has been
interrupted
Check for 12v at center pin of remote socket on
controller. Check continuity of remote lead
connector from center pin to either side pin with
remote control pendant on/off switch in both
positions. Replace remote control pendant if there
is no continuity.
Winch will power out but not
power-in
Failure in remote
control
pendant
switch or wiring
Check for 12v at center pin of remote socket on
controller. Check continuity of remote lead
connector from center pin to either side pin with
remote control pendant on/off switch pushed in
both positions. Replace remote control pendant if
there is no continuity.
Failure of
components or
wiring inside
controller
Check for 12v at center pin of remote socket on
controller. Check continuity of remote lead
connector from center pin to either side pin with
remote control pendant on/off switch in both
positions. Replace remote control pendant if there
is no continuity. If none of these corrective actions
resolves problem, return the trolley to Starter.
Winch will power-in but not
power-out
Power to remote
control pendant
has been
interrupted
Check for 12v at center pin of remote socket on
controller. Check continuity of remote lead
connector from center pin to either side pin with
remote control pendant on/off switch pushed in
both positions. Replace remote control pendant if
there is no continuity
Motor tries to power-out but
winch stalls or locks-up
Load brake failure Service or replace load brake.
Winch operates in both
directions but will not lift
rated load
Low voltage at
winch
A) Check condition of battery.
B) Check all power wiring and connections for
corrosion. Clean and tighten connections
Winch slows down and
stalls during power out
Brake needs
service
Service or replace load brake.
Winch vibrates badly or is
noisy during use under load
Brake needs
servicing
Service or replace load brake.
Summary of Contents for ARKANE
Page 12: ...11 MU0091 B...
Page 15: ...14 MU0091 B...
Page 20: ...19 MU0091 B...
Page 39: ...38 MU0091 B...
Page 40: ...39 MU0091 B...
Page 41: ...40 MU0091 B...
Page 42: ...41 MU0091 B...
Page 43: ...42 MU0091 B...
Page 45: ...44 MU0091 B 11 6 Declaration of conformity CE 11 6 D claration de conformit CE...
Page 46: ...45 MU0091 B NOTE...
Page 47: ...46 MU0091 B NOTE...