Emergency Retract Mode
Use this procedure when there is
NO
loss of power or electrical problem with the system.
1. Remove the touchpad (Fig 4) from the wall.
2. Prior to clearing the MAJOR fault, record the number of
RED & GREEN flashes observed on the touchpad (Fig 6).
This information will help your dealer/service center in
troubleshooting the slideout system.
3. Press and hold the SET STOPS/CLEAR FAULTS button
on the back of the touchpad for five (5) seconds (Fig 2). Both RED & GREEN LEDs
will be on solid while pressing this button. After 5 seconds, the GREEN LED will
begin flashing and the RED LED will remain solid on.
4. The unit is now ready to retract the room. Press and hold the ROOM SLIDEOUT MO-
TOR buttons 1 and 2 on the back of the touchpad (Fig 3).
Press the IN button on the front of the wall touchpad until the room is fully retracted. If one
side of the room needs to retract further in order to get a good seal, press and hold the motor
button (Fig 3) corresponding to
ONLY
the motor you want to move. Press the IN button on
the front of the touchpad to retract the room the remainder of the way.
5. Re-install the wall touchpad.
6.
Take the unit to an OEM certified dealer for repairs.
Manually Retract Room with Ratchet and Socket
If the power is lost to the slideout motor(s) or the override mode above will not work, the
room may be manually retracted using a ratchet and socket attached to the end of the coupler
(Fig 11).
1. Gain access to the VERTICAL CHANNEL assembly from inside or outside of the
coach (whichever is more convenient). Remove the trim and flange pieces on the slide
-
out room box.
2. If applicable, remove the top screw from the bulb seal at the top of the VERTICAL
CHANNEL (Fig 8).
3. Pull down the bulb seal and remove the motor cover (Fig 9). The motor seal may stick
to the bulb seal.
4. Using a pick tool, remove the end of the retaining spring from the motor spring clip
(Fig 10A). If not equipped with a retaining spring, loosen the motor retaining screw
(Fig 10B).
It is very important to note that during this procedure, the slideout control
has NO stop locations. Use a second person to assist in determining when
the room is retracted. Damage to the room can occur if the room is retracted
too far.
NOTE:
After overriding the system, the room control will need to be
re-programmed by an OEM authorized dealer.
Maintenance Record
Table of Contents
Summary of Contents for Telluride 2021
Page 1: ...0311723 2021 FIFTH WHEELS 2021 Owner s Manual Asubsidiary of Thor Industries Inc ...
Page 2: ......
Page 32: ...30 Section 2 Occupant Safety Notes Table of Contents Maintenance Record ...
Page 40: ...38 Section 3 Pre Travel Information Notes Table of Contents Maintenance Record ...
Page 108: ...106 Section 7 Fuel Propane System Notes Table of Contents Maintenance Record ...
Page 132: ...130 Section 8 Plumbing System Notes Table of Contents Maintenance Record ...
Page 144: ...142 Section 10 Appliances Notes Table of Contents Maintenance Record ...
Page 146: ...144 Section 11 Electronics Notes Table of Contents Maintenance Record ...
Page 164: ...162 Section 14 Travel Camping Storage Checklists Notes Table of Contents Maintenance Record ...