75
Section 5: Slideout Systems
5. Turn
ON
the on/off switch or key.
6. Press and hold the OUT button (Fig 4). To retract, press
and hold the IN button. There will be a slight delay be-
fore the room begins moving.
7. The GREEN LED should be solid ON when room is in
motion.
8. Release the OUT button when the room is fully extended or the IN button when fully
retracted, and stops moving.
9. Turn
OFF
the on/off switch or key.
Fault Diagnostics / Troubleshooting:
The control has the ability to detect and display several faults. When a fault is detected,
room movement stops and two different LEDs will flash in a pattern.
The RED FAULT CODE LED (Fig 4) will flash a number of times corresponding to a spe
-
cific fault code (refer to the Fault Code Chart).
The GREEN ROOM MOVEMENT LED (Fig 4) will flash GREEN a number of times cor
-
responding to which motor has the associated fault.
Example: (4) RED flashes and (2) GREEN flashes indicate a motor fault on motor 2.
MAJOR and MINOR faults
; faults must be cleared for the room to operate normally.
MINOR
faults can be cleared by pushing and releasing the
IN
or
OUT
buttons on
the wall touchpad (Fig 4).
MAJOR
faults must be cleared by pushing and releasing the SET STOPS/CLEAR
FAULTS button located on the back of the wall touchpad (Fig 2).
F a u l t
Code
F a u l t
Type
Fault Codes
Description
Possible Cause
Possible Solution
1
Major Stops not
programmed
-Stops have not been
set
-Stops were cleared
-Stops were improperly
set
Steps need to be pro-
grammed by an authorized
service facility.
2
Minor System Fault
-Obstruction present
-Excessive system drag
Run room in opposite direc-
tion. If it continues to move
in the opposite direction,
remove obstruction, exces-
sive weight in room or repair
of damaged component. If
room stops moving in oppo-
site direction, observe fault
code and refer to this chart
NOTE:
For MAJOR faults, the control must be overridden by
following the EMERGENCY RETRACT MODE in the
OVERRIDE
MODES section.
Maintenance Record
Table of Contents
Summary of Contents for Telluride 2021
Page 1: ...0311723 2021 FIFTH WHEELS 2021 Owner s Manual Asubsidiary of Thor Industries Inc ...
Page 2: ......
Page 32: ...30 Section 2 Occupant Safety Notes Table of Contents Maintenance Record ...
Page 40: ...38 Section 3 Pre Travel Information Notes Table of Contents Maintenance Record ...
Page 108: ...106 Section 7 Fuel Propane System Notes Table of Contents Maintenance Record ...
Page 132: ...130 Section 8 Plumbing System Notes Table of Contents Maintenance Record ...
Page 144: ...142 Section 10 Appliances Notes Table of Contents Maintenance Record ...
Page 146: ...144 Section 11 Electronics Notes Table of Contents Maintenance Record ...
Page 164: ...162 Section 14 Travel Camping Storage Checklists Notes Table of Contents Maintenance Record ...