background image

16

Copyright © 2020. All rights reserved • 95 North Oak Street • Kendallville, IN 46755

WARRANTY

This product is warranted for one year from the date of purchase. Subject to the conditions hereinafter 
set forth, the manufacturer will repair or replace to the original consumer, any portion of the product 
which proves defective due to defective materials or workmanship. This warranty does not cover 
replacement parts for failure due to normal wear and tear. To obtain warranty service, contact the 
dealer from whom the product was purchased. The manufacturer retains the sole right and option to 
determine whether to repair or replace defective equipment, parts or components. Damage due to 
conditions beyond the control of the manufacturer is not covered by this warranty.

THIS WARRANTY WILL NOT APPLY: 

(a)  To defects or malfunctions resulting from failure to properly install, operate or maintain the unit in 

accordance with printed instructions provided; 

(b)  to failures resulting from abuse, accident or negligence or use of inappropriate chemicals or 

additives in the water; 

(c)  to normal maintenance services and the parts used in connection with such service; 

(d)  to units which are not installed in accordance with normal applicable local codes, ordinances and 

good trade practices; and 

(e) if the unit is used for purposes other than for what it was designed and manufactured.

RETURN OF WARRANTED COMPONENTS: Any item to be repaired or replaced under this warranty 
must be returned to the manufacturer at Kendallville, Indiana or such other place as the manufacturer 
may designate, freight prepaid.

THE WARRANTY PROVIDED HEREIN IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES, AND MAY 
NOT BE EXTENDED OR MODIFIED BY ANYONE. ANY IMPLIED WARRANTIES SHALL BE LIMITED TO 
THE PERIOD OF THE LIMITED WARRANTY AND THEREAFTER ALL SUCH IMPLIED WARRANTIES ARE 
DISCLAIMED AND EXCLUDED. THE MANUFACTURER SHALL NOT, UNDER ANY CIRCUMSTANCES, BE 
LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES, SUCH AS, BUT NOT LIMITED TO 
DAMAGE TO, OR LOSS OF, OTHER PROPERTY OR EQUIPMENT, LOSS OF PROFITS, INCONVENIENCE, 
OR OTHER INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY TYPE OR NATURE. THE LIABILITY 
OF THE MANUFACTURER SHALL NOT EXCEED THE PRICE OF THE PRODUCT UPON WHICH SUCH 
LIABILITY IS BASED.

This warranty gives you specific legal rights, and you may have other rights which vary from state to 

state. Some states do not allow limitations on duration of implied warranties or exclusion of incidental 
or consequential damages, so the above limitations may not apply to you.

In those instances where damages are incurred as a result of an alleged pump failure, the 

Homeowner must retain possession of the pump for investigation purposes.

Summary of Contents for 025191 1.65HP

Page 1: ...erial Number Purchase Date Questions problems missing parts Before returning to your retailer call our customer service department at 1 800 742 5044 7 30 a m 5 00 p m EST Monday Friday ATTACH YOUR REC...

Page 2: ...D AND FOLLOW ALL INSTRUCTIONS in this owner s manual and on the equipment Failure to follow instructions can cause severe injury and or death SUCTION ENTRAPMENT HAZARD Suction inlets and outlets and o...

Page 3: ...ltration system pumps and heater must be positioned so as to prevent their being used as means of access to the pool by young children Never operate or test the circulation system at more than 50 PSI...

Page 4: ...ool spa or hot tub and metal piping except gas piping and conduit within 5 ft 1 5 m of inside walls of swimming pool spa or hot tub Reference NEC codes for all wiring standards including but not limit...

Page 5: ...t but not over tightened Though the pump is designed for outdoor use it is strongly advised to protect the electrical components from the weather Select a well drained area one that will not flood whe...

Page 6: ...than the GPM rating of the pool filter If the pump is rated higher than the filter the filter is undersized and will not work properly The size of your pool pipes determines the maximum flow rate for...

Page 7: ...the entire threaded portion of the male fitting with one to two layers of tape Wind the tape clockwise as you face the open end of the fitting beginning at the end of the fitting The pump suction and...

Page 8: ...a firm level base or pad with screws or bolts The base MUST be solid level rigid vibration free and protected from both weather and pool splash Make sure pump inlet height is as close to the water lev...

Page 9: ...inlet 6 Fill pump and trap with water replace trap lid and check system for leaks If no leaks proceed with pump startup NOTE DO NOT START PUMP if any leaks are present in the system After startup che...

Page 10: ...dicates electrical problem If GFCI trips and won t reset consult electrician to inspect and repair electrical system Fire Hazard Match supply voltage to motor nameplate voltage Ensure that the electri...

Page 11: ...grounding bonding and general wiring procedures Use a solid copper conductor per code Run wire from external bonding lug to reinforcing rod or mesh Connect per code solid copper bonding wire to the p...

Page 12: ...charged from valve Failure to do so could result in severe personal injury NEVER OPERATE THE PUMP WITHOUT WATER Water acts as a coolant and lubricant for the mechanical shaft seal NEVER run pump dry R...

Page 13: ...ycol as antifreeze in your pool spa system Propylene glycol is non toxic and will not damage plastic system components Other anti freezes are highly toxic and may damage plastic components in the syst...

Page 14: ...sing is filled with water and cover O Ring is clean Ensure O Ring is properly seated in the cover O Ring groove Ensure O Ring is lubricated and that strainer cover is locked firmly in position Loose c...

Page 15: ...tricted or undersized suction line or leak at any joint low water level in pool and unrestricted discharge return lines 1 Correct suction condition or throttle return lines if practical Holding hand o...

Page 16: ...and good trade practices and e if the unit is used for purposes other than for what it was designed and manufactured RETURN OF WARRANTED COMPONENTS Any item to be repaired or replaced under this warr...

Page 17: ...a de compra Preguntas problemas piezas faltantes Antes de volver a la tienda llame a nuestro Departamento de Servicio al Cliente al 1 800 742 5044 de lunes a viernes de 7 30 a m a 5 00 p m hora est nd...

Page 18: ...pietario y en el equipo No seguir las instrucciones puede causar lesiones graves y o la muerte PELIGRO DE ATRAPAMIENTO POR SUCCI N Las entradas y salidas de succi n y o las tapas de las salidas de suc...

Page 19: ...la piscina Nunca opere o pruebe el sistema de circulaci n a m s de 345 kPa 50 PSI Nunca cambie la posici n de la v lvula de control del filtro mientras la bomba est en funcionamiento Para reducir el r...

Page 20: ...tuber as met licas excepto las tuber as de gas y a los conductos que se encuentran a menos de 1 5 m 5 de las paredes interiores de la piscina spa o jacuzzi Consulte los c digos NEC para ver todas las...

Page 21: ...s pero no demasiado Aunque la bomba est dise ada para usar en exteriores se recomienda proteger los componentes el ctricos de las inclemencias del clima Seleccione un lugar con buen drenaje uno que no...

Page 22: ...el filtro de su alberca El filtro de su alberca tiene un flujo m ximo que se mide en GPM La clasificaci n de GPM de la bomba debe ser inferior a la calificaci n de GPM del filtro de la alberca Si la b...

Page 23: ...ci n roscada del conector macho con una o dos capas de cinta Enrolle la cinca en el sentido de las agujas del reloj mirando el extremo abierto del conector empezando por el final del conector Los puer...

Page 24: ...plir con tornillos y pernos La base DEBE ser s lida r gida nivelada y sin vibraciones y protegido tanto del clima como de las salpicaduras de la piscina Comprobar que la altura de la entrada de la bom...

Page 25: ...a con agua vuelva a colocar la tapa de la trampa y compruebe que no haya fugas en el sistema Si no hay fugas proceda con el arranque de la bomba NOTA NO ARRANQUE LA BOMBA si hay fugas en el sistema Lu...

Page 26: ...fica que hay un problema el ctrico Si el GFCI se dispara y no se restablece p dale a un electricista que inspeccione y repare el sistema el ctrico Peligro de incendio Iguale el voltaje de alimentaci n...

Page 27: ...metal empalmados lo que puede provocar una descarga el ctrica si se conecta a tierra o hay un cortocircuito Consulte los c digos NEC para ver todas las normas de cableado incluyendo entre otros proce...

Page 28: ...en lesiones personales graves NUNCA OPERE LA BOMBA SIN AGUA El agua act a como refrigerante y lubricante para el sello del eje mec nico NUNCA ponga en marcha la bomba en seco Poner en marcha la bomba...

Page 29: ...ol como anticongelante en su sistema de piscina spa El propilenglicol no es t xico y no da ar los componentes de pl stico del sistema Otros anticongelantes son altamente t xicos y pueden da ar los com...

Page 30: ...ua y que la junta t rica de la tapa est limpia Aseg rese de que la junta t rica se encuentre correctamente en la ranura de la junta t rica de la tapa Aseg rese de que la junta t rica est lubricada y q...

Page 31: ...restringida o de menor tama o o fuga en alguna junta nivel bajo de agua en la piscina y l neas de retorno de descarga sin restricciones 1 Corrija la condici n de succi n o regule las l neas de retorno...

Page 32: ...buenas pr cticas comerciales aplicables y e si la unidad se utiliza para fines para los cuales no est destinada ni fabricada DEVOLUCI N DE COMPONENTES EN GARANT A Cualquier elemento a ser reparado o...

Reviews: