8
Copyright © 2020. All rights reserved • 95 North Oak Street • Kendallville, IN 46755
INSTALLATION:
Pump inlet
1
Shut Off
Valve
Pump
Inlet Pipe
Pool
Skimmer
Pipe Union
2
Shut Off
Valve
Pump Discharge Line
Filter Inlet
Pipe Union
3
NOTE:
Before installing the pump check your
voltage requirements.
The pump is preset to
230V. If your power source is 115V see page 10
and follow instructions to change wiring according
to the diagrams.
1. Install pump on a firm, level base or pad with
screws or bolts. The base MUST be solid, level,
rigid, vibration free and protected from both
weather and pool splash. Make sure pump inlet
height is as close to the water level as possible.
2. Attach discharge line from pump to filter inlet
using a pipe union and attach shut-off valve.
Use a short and direct suction pipe. Be sure to
incorporate a straight portion of pipe that is at
least 5 times longer than the diameter of the
pump inlet pipe.
3. Use a pipe union to attach discharge line from
pump to filter inlet and attach shut-off valve.
Suction line pipe must the same diameter or
larger than the discharge line.