![Stanley Theta Controller User Manual Download Page 39](http://html.mh-extra.com/html/stanley/theta-controller/theta-controller_user-manual_1359692039.webp)
Theta Controller
Programming
35
Controller Tab Screens
Options Screen
2.8.5.3.1 About Tab
This tab displays information about the
controller. These values are read only unless
blank. The Model and Serial fields can be
written to once.
2.8.6
Analyze
Analyze Screens
Options Screen
Analyze
displays tool and controller diagnostic information, traces and I/O status.
2.8.6.1
TOOL tab
Use this tab to perform diagnostics during
troubleshooting operations. This tab shows
live status of the following events:
Transducer Health – The thickness of the vertical line within the horizontal bar indicates
transducer signal (a thicker line means more load is applied). The line should be thin when no
load is applied to the tool. This indicates the zero point of the transducer. Once the zero point
of the line reaches the tick mark, on either side of center, the transducer needs to be replaced.
Transducer Torque – Provides a live transducer torque value during the tightening cycle.
Transducer Current – The transducer is powered with a constant current value. This current
should be present and not varying. See section 1.3 Specifications, Layout and Display for
limits.
Controller DC Bus voltage – The bus should always be around 320 VDC. The minimum is
285 VDC and the maximum is 400 VDC.
Controller AC Supply Voltage / Frequency – See section 1.3 Specifications, Layout and
Display for controller AC volts specification.
Tool Temperature – Temperature is not measured during tool operation. Interacts with the
Temperature Limit parameter. See section 2.8.3.7 Tool Tab for further information.
Tool Output Angle – Identifies number of circular degrees of rotation on the output of the tool.
Resets at each start.
Tool Output Speed – Real time speed of the output of the tool.