![Stanley Theta Controller User Manual Download Page 37](http://html.mh-extra.com/html/stanley/theta-controller/theta-controller_user-manual_1359692037.webp)
Theta Controller
Programming
33
Restore Factory Defaults Screens
Options Screen
After pressing the button the screen returns to
run mode.
2.8.5
Service
Tool Tab Screens
Options Screen
The Service area presents information about the tool and controller. Users must have TOOL or
ADMINISTRATOR access level to modify any parameters here.
2.8.5.1
Tool
All tool parameters are stored by the tool
memory board located in the tool’s handle.
This area reads/writes those values on the tool
memory board, not in the controller
2.8.5.1.1 About Tab
This tab displays information about the tool
currently attached to the controller. Only the
Serial value field is editable. If there is no
serial number, enter one (can only be entered
one time).
Use the right arrow to move to the next tab or press EXIT to save the changes and return to the
Run screen. See section 2.8.1.7 Setup: Exit for further information.
2.8.5.1.2 Counters Tab
Each of the three counters increments at the
same time after an OK tightening cycle.
Odometer – Cannot be reset. Indicates the
total number of OK tightening cycles the
attached tool has performed over its lifetime.
PM Counter – Causes the preventive
maintenance LED to illuminate (on front
panel and tool) when this value exceeds the
PM Threshold.
Trip Counter – Counts the number of OK
tightening cycles between resets.
Use the RESET button to reset (back to zero)