ENGLISH
(Original instructions)
4
ADDITIONAL POWER TOOL SAFETY WARNINGS
WARNING!
Additional safety warnings for drills
• Wear ear protectors when impact drilling.
Exposure to
noise can cause hearing loss.
• Use auxiliary handle(s), if supplied with the tool.
Loss
of control can cause personal injury.
• Hold power tool by insulated gripping surfaces, when
performing an operation where the cutting accessory
may contact hidden wiring or its own cord.
Cutting
accessory contacting a "live" wire may make exposed
metal parts of the power tool "live" and could give the
operator an electric shock.
• Use clamps or another practical way to secure and
support the workpiece to a stable platform. Holding the
work by hand or against your body leaves it unstable and
may lead to loss of control.
• Before drilling into walls, floors or ceilings, check for the
location of wiring and pipes.
• Avoid touching the tip of a drill bit just after drilling, as it
may be hot.
• This tool is not intended for use by persons(including
children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning
use of the appliance by a person responsible for their
safety. Children should be supervised to ensure that they
do not play with the appliance.
• The intended use is described in this instruction manual.
The use of any accessory or attachment or performance of
any operation with this tool other than those recommended
in this instruction manual may present a risk of personal
injury and/or damage to property.
Cable cross-sectional
area (mm
2
)
Cable rated
current (Ampere)
0.75
6
1.00
10
1.50
15
2.50
20
4.00
25
Cable length (m)
7.5 15
25
30
45
60
Voltage
Amperes
Cable rated current (Ampere)
110-127
0 - 2.0
6
6
6
6
6
10
2.1 - 3.4
6
6
6
6
15 15
3.5 - 5.0
6
6
10 15 20 20
5.1 - 7.0
10 10 15 20 20 25
7.1 - 12.0
15 15 20 25 25
-
12.1 - 20.0 20 20 25
-
-
-
220-240
0 - 2.0
6
6
6
6
6
6
2.1 - 3.4
6
6
6
6
6
6
3.5 - 5.0
6
6
6
6
10 15
5.1 - 7.0
10 10 10 10 15 15
7.1 - 12.0
15 15 15 15 20 20
12.1 - 20.0 20 20 20 20 25
-
ELECTRICAL SAFETY
Your tool is double insulated; therefore no earth
wire is required. Always check that the main voltage
corresponds to the voltage on the rating plate.
WARNING
!
If the power cord is damaged, it must
be replaced by the manufacturer, authorized
STANLEY Service Center or an equally qualified
person in order to avoid damage or injury. If the
power cord is replaced by an equally qualified
person, but not authorized by STANLEY, the
warranty will not be valid.
USING AN EXTENSION CABLE
If it is necessary to use an extension cable, please use an
approved extension cable that fits the tool’s power input
specifications. The minimum cross-sectional area of the
conducting wire is 1.5 sq. mm. Cables should be untangled
before reeling up.
WARNING! To reduce the risk of injury, the user
must read the instruction manual before use.
Wear ear protection.
Wear safety glasses or goggles.
V
Volts
Direct Current
A
Amperes
n
0
No-Load Speed
Hz
Hertz
Class II Construction
W
Watts
Earthing Terminal
min
minutes
Safety Alert Symbol
Alternating
Current
/min.
Revolutions or
Reciprocation per
minute
LABELS ON TOOL
The label on your tool may include the following symbols:
Summary of Contents for STDR5510
Page 2: ...ENGLISH Original instructions 2 A B D E 2 1 3 4 7 6 5 3 B1 B2 C1 C2 9 8 6 5...
Page 13: ...STANLEY STDR5510 STDR5510C 1 a b c 2 a b c d e f 3 a b c d e 13...
Page 14: ...14 f g h 4 a b c d e f g h 5 a...
Page 16: ...16 2017 XX JN 1 1 STDR5510 1 A 1 2 3 4 5 6 7 8 STDR5510 9 STDR5510 1 4 6 1 2 5 6 9 8 1 1 2 D 3...
Page 17: ...17 3 1 2 7 E F 5 16 8 1 2 13 5 32 4 3 16 5 STANLEY STANLEY STANLEY STANLEY STANLEY STANLEY...
Page 20: ...STANLEY STDR5510 STDR5510C 1 a b c 2 a b c d e f 3 a b c d e f 20...
Page 21: ...21 g h 4 a b c d e f g h 5 a...
Page 23: ...23 B1 4 6 1 2 5 6 9 8 1 C1 2 D 3 3 1 2 7 E F...
Page 35: ......
Page 36: ...N646597 01 2019...