NEVER LEAVE VENTILATOR UNATTENDED WHILE CONNECTED TO A POWER SOURCE
© 2017, Obelis S.A Registered Address:
Bd. Général Wahis, 53, 1030 Brussels, Belgium
Problem
Possible Cause
Solution
Burner does not light
1. Air in gas line.
2. Gas pressure from cylinder too low
3. LP cylinder valve turned off
4. Obstruction in air passageway
5 Dirt in nozzle
6. Safety switch in cylinder valve
engaged
1. Depress the control knob for at least 30
seconds to remove any air in line.
2. Check LP cylinder pressure. Tank may be
empty
3. Open LP cylinder valve
4. Inspect and clean heater housing
5. Blow out, or otherwise clean the nozzle
6. Close LP cylinder valve. Wait one minute for
switch to click off. Re-open LP cylinder valve
slowly
Heater stops running by
itself
1. Thermocouple damaged
2. Gas control valve damaged
3. Gas leak
4. Out of fuel
5. Thermocouple not in contact with
pilot flame
1. Replace thermocouple
2. Replace gas control valve
3. Check all connections for leaks and repair
4. Replace LP cylinder
5. Clean inside of burner housing
No spark is created when
ignited
1. Gas control valve damaged
2. Loose or disconnected igniter wire
3. Broken igniter wire
1. Replace gas control valve
2. Tighten or reconnect loose wire
3. Replace igniter wire
Troubleshooting Guide
Specifications subject to change without notice
4
THERMAL POWER(kW/BTU)
3.4 / 11,687
IGNITION
PIEZO
FUEL CONSUMPTION (g/h)
246
WEIGHT (kg)
2.24
MAX OPERATING HOURS
129
GAS TYPE
G30,G31 and their
mixtures
CATEGORY
I3B/P(50)
PRESSURE
(G30) 50 mbar
(G31) 50 mbar
GAS CYLINDER SIZE
5kg-15kg
HOSE TYPE (WHEN SUPPLIED)
Rubber or Plastic hoses
complied with BS EN
16436-1:2014
HOSE LENGTH (WHEN SUPPLIED)
1.0m-1.5m
REGULATOR TYPE
(WHEN SUPPLIED)
LPG Gas Regulator
OUTLET PRESSURE
Butane at 50 mbar
Propane at 50 mbar
Specifications