Fluids for Mobile Hydraulic
Tool Circuits
Recommended Fluid
s
ITEM
U.S.A.
METRIC
BRAND
BIODEGRADABLE
DESCRIPTION
The specification listed here will
provide good all season operation
if your circuit is of proper design
and normal maintenance is per-
formed.
(Periodic filter change,
draining of condensate, etc.
The fluids listed here work well
over a wide temperature range at
start-up, allow moisture to settle
out, and resist biological growth
likely in cool-operating hydraulic
Circuits.
These fluids are recommended by
Stanley Hydraulic Tools for use in
our tools. Other fluids that meet or
exceed the specifications of these
fluids may also be used.
P/N 15596 04/98 .5M
Hydraulic Recommendations
SPECIFICATIONS
RECOMMENDED FLUIDS
Viscosity (Fluid Thickness) 50 F 450 SSU Max
10 C 95 Centistokes Max.
Viscosity (Fluid Thickness) 100 F 130-225 SSU
38 C 27-42 Centistokes
Viscosity (Fluid Thickness) 140 F 85 SSE Min.
60 C 16.5 Centistokes Min.
Pour Point (Min. for cold startup)
-10 F
23 C
Viscosity Index
(ASTM D2220) 140 Minimum
Demulsibility
(ASTM D1401) 30 Minutes Max.
Flash Point
(ASTM D92) 340 F Min.
Rust Inhibition
(ASTM D665 A&B) Pass
Oxidation
(ASTM D943) 1000 Hours Min.
Pump Wear Test
(ASTM D2882) 60 mg Max.
AMS-Oil
No
Hydraulic Fluid MN 150 SSU, 100 V.I.
Chevron
No
AW-MV-32
Exxon
No
“Univis” J-26
Mobil
No
D.T.E. 13
Gulf
No
“Harmony” AW-HVI-1 50-32
Shell
No
“Lo-Hydraul” 32
Sun
No
“Sunvis” 805 MG
Texaco
No
“Rando” HD-AZ
Union
No
“Unax” AW-WR-32
Mobil
Yes
EAL 224H
Texaco
Yes
BioStar 32
Terresole
Yes
EnviroLogic 132
Shell
Yes
Naturelle HF-E-32
Pennzoil
Yes
Pennzsafe Sl200
°
°
°
°
°
°
°
°
°
Summary of Contents for DL09150