15
DRAINING
Key-operated drain taps to BS 2879 should be
provided in accessible positions in all low parts of
the system. However, it should be noted that there
may be short sections of pipework, e.g. when
passing under doorways, that may not be possible to
drain.
INTERNAL PUMP THERMOSTAT
This appliance has the capability for switching the
circulating pump ‘on’ and ‘off’ automatically. To wire
in the pump, connect the phase to terminal marked
CIRC Pump (L) and connect the Neutral to terminal
marked CIRC Pump (N). The earth wire is to be
connected into the earth block.
The connection circuit board/control panel is located
within the appliance beneath the warming oven.
(See Fig.17)
f.
Replace blanking plates.
g.
Plug the boiler tappings on the left hand side of
the boiler with 1” BSP plugs.
h.
Test for leaks.
Fig. 16
Fig.17
WATER CIRCUIT TEMPERATURE
The return water temperature should be maintained
at not less than 50
°
C (122
°
F) so as to avoid
condensation forming within the boiler.
CARE FOR YOUR CENTRAL HEATING SYSTEM
The use of suitable corrosion inhibitors and anti
freeze solution in your heating system is essential to
minimise black oxide, sludge and scale build-up,
which effects efficiency.
In hard water areas the use of a suitable limescale
preventer / remover is advised.
Use only quantities specified by the water treatment
product manufacturer. Only add to the heating
system after flushing and finally refilling. Refer to
BS 7953.
INDIRECT DOMESTIC CYLINDER
The cooker must only be connected to an indirect
cylinder of no less than 180 litres using 28mm
diameter flow and return piping. It is recommended
that the cylinder is lagged together with pipework
with runs in excess of 4 meters (12’).
SERVICING
To ensure continued efficient and safe operation of
the appliance, it is recommended that it is checked
and serviced by an Authorised Stanley Service
Engineer at least once a year.
In the event that the cooker is not serviced by such
an engineer, at least once a year, Waterford Stanley
Limited regrets that it can entertain no claims
whatsoever in respect of alleged problems in the
efficiency or safety of the cooker supplied.
Blanking Plates
50mm Knockouts RH Boiler
Connections
IMPORTANT:-
Flexible oil lines should be inspected at each
and every service visit. It is important in the
interest of safety that flexible lines are changed
at regular intervals and should be changed
immediately in all the following cases:
1.
The oil line has been in use in the
cooker for 3 years or more.
2.
The date code on the oil hose shows
as five years or older.
(whichever of the above comes first)
3.
The oil hose shows signs of being
kinked or damaged, irrespective of
date life service span.