9
FLUE SYSTEMS
PRE-INSTALLATION CHECK
Before installing the cooker, check that the chimney
is clean and clear of obstructions. Cracked
brickwork and leaking joints should be made good.
You must reassure yourself (with the benefit of
professional advice) that the brickwork and system
generally is of the standard suitable to support the
cooker in a safe and efficient manner.
Where flue piping passes through a closure plate
with a sliding door, ensure that the pipe continues up
and is ultimately connected to the flue liner and well
sealed with fire cement.
Do not connect to a flue serving another appliance.
Always ensure that the connection is to a chimney of
the same size - never connect to one of smaller
dimensions. Flues wholly constructed of single skin
pipe
are
not
recommended
under
any
circumstances. Due to their inability to retain heat
such flues will inevitably give rise to the formation of
condensation.
IT IS NOT RECOMMENDED TO CONNECT TO A
FLUE SMALLER THAN 150mm (6”) OR IN
EXCESS OF 175mm (7”) DIAMETER.
150mm (6”) Diameter Flue Liner
Fig. 8.
Note:
Fill voids and area around liner with vermiculite or a
comparable approved material. (See Fig. 8)
Fig.7
CHIMNEY
Generally the most effective chimney for oil is one
that is straight, avoid offsets and terminate with a
straight sided pot.
Where the flue passes through a combustible
material, a twin wall solid packed insulated chimney
connector must be used and must come flush with
the outer surface of the material and run all the way
to the masonry chimney or to the point of termination
of the factory made chimney. (See Fig.6)
(You should discuss the installation of your Stanley
cooker with your builder in this regard in the case of
a newly fitted kitchen.
When installing a non combustible worktop, it is
necessary to allow adequate clearance for the
removal of the hob.
Vermiculite or a
comparable material
150mm (6”)
flexible flue liner
Fire Sealing
Cement
Closure Plate
Flue Diameter of
150mm (6”)
Cleaning Plate
Simmer
Plate
Pipe Bend
Cleaning Plate
Hotplate
Flex Pipe
Adaptor
Seal Bend to
Connecting Collar