Installation Instructions for 83KM/93KM–85KM/95KM IDH Max Cylindrical Locks
BEST ACCESS SYSTEMS
a Product Group of Stanley Security Solutions, Inc
Preparing the door and door jamb
8
7
Pull field wire harness through door
.
1 Route the field wire harness (connected to the PCB)
through the wire routing hole in the fire plate and into
the hole drilled through the door to the hinge mortise.
2 From the latch edge of the door, fish the field wire
harness through the door to the hinge mortise.
3 Make sure there are 3 to 4 inches of slack in the field
wire harness to allow access to the control electronics
circuit board in the inside trim.
Figure 7
Pulling the field wire harness through the
door
Hinge mortise
Field wire
harness
Fire plate with PCB
Field harness &
RH/RHRB reader
wire hole
Inside of door