Installation Instructions for 83KM/93KM–85KM/95KM IDH Max Cylindrical Locks
BEST ACCESS SYSTEMS
a Product Group of Stanley Security Solutions, Inc
Installing the panel interface module
18
22
Install wire transfer hinge
1 Trim the four wires of the field wire harness, which you
pulled through the hinge edge of the door in Task 7.
Leave sufficient length to connect to the wire transfer
hinge.
2 Splice the power and communication field wiring to the
four pairs of leads on the frame side of the hinge,
following the hinge manufacturer’s instructions.
3 Splice the four field harness wires (listed in the table
below) to the four pairs of leads on the door side of the
hinge, matching each pair of leads to its corresponding
field wire.
4 Insert the wires and splice connectors into the holes or
pockets in the door and frame, being careful not to pinch
the wires. Install the wire transfer hinge.
23
Install lock power supply (optional)
If you are providing a separate power supply for the lock
instead of providing power via the panel interface
module, connect the two power field wires (run from the
wire transfer hinge) to the power supply. Make sure
power (12 volts DC) and ground are connected properly.
Follow the instructions provided by the power supply
manufacturer. Do not plug in the power supply yet.
Note: For specifications for the power supply, see
Components checklist, on page 2.
24
Mount panel interface module
Peel the paper off the adhesive tape affixed to the back of
the panel rail and press the panel rail into position.
Note: Mount the panel interface module in the enclosure
with the access control panel/reader interface, if possible.
Wire
Color
Ground
Black
12 VDC
Red
Com+
Orange
Com–
Green
Figure 21 Installing the wire transfer hinge
Access holes
Field wire
harness leads
Wire transfer
hinge
Door frame
Field wires
Splice
connectors
Door
Figure 21 Mounting the panel interface module
Adhesive
tape