Table 1. FIS Procedure Using Pushbuttons
Step
Description
Display
Index
Value
Status
Code
1
Set Function switch to
Closed
.
2
Turn power on.
3
Unlock keypad.
99
0
00
4
Restart FIS.
96
1
A0
5
Select door type (Refer to Table 2).
0
Refer to Table 2
A0
6
Select Motor 1 Handing.
1
00 = Right hand
01 = Left hand
A0
7
Select Motor 2 Handing.
2
00 = Right hand
01 = Left hand
A0
8
Accept FIS. Display will show
A1
.
3
1
A1
9
Make changes: Safety Logic.
(
NOTE
: If there are no sensors
connected, leave value of 00).
11
Safety Logic. INDEX 11 - 00 to 15
00 = Sensor
01 = Sentrex
02 = Carpet
03 = Carpet 12 Sec.
04 = Non-Monitored Bi-Fold
05 = Monitored DM & OHP. ACT, STL
& SAF, both single & pair
06 = Monitored DM & OHP Dual
Egress. STL, ACT, STL & SAF
07 = Monitored OHP & Photobeam.
SAF & Photobeam
08 = Monitored DM ACT. ACT both
single & pair
09 = Monitored OHP Bi-Fold. SAF
10 = Monitored DM. ACT & STL both
single & pair
11 = Two OHP Monitored Bi-fold. SAF,
Bi-Fold/Swing
12 = Monitored Hub Based Sensors.
ACT & STL
13 = Swing-Guard T
14 = Monitored DM Stall & OHP both
single and pair. STL & SAF
15 = Monitored DM Stall & OHP Dual
Egress. STL & SAF
A1
10 Lock Keypad.
99
01
00
11 Final Tune in.
--
--
--
ABBREVIATIONS
DM
Door Mounted Sensors
OHP Overhead Presence Sensor
ACT
Activation Side Presence Sensor
STL
Stall Presence Sensor
SAF
Safety Presence Sensor
Index Tables