iQ Control Box
10.18.2019
1.800.7.ACCESS • www.stanleyaccess.com • Document # 204143 REV 5 45
Cop
yr
ight 2019, S
tanley Ac
cess T
echnologies, LL
C. All rights r
es
er
ved. R
epr
oduction
in whole or in p
ar
t without the expr
ess wr
itt
en permission o
f S
tanley is pr
ohibit
ed.
Attachment 9
Hand Held Device Troubleshooting Aid—Swing/Fold
(Sheet 1 of 1)
Terminal and Pin
Description
State
TB1-8
Bodyguard-T Data Output
Dark = door open
Light = door closed
Function Switch States for TB2
Hold Open
OFF
Auto ON
Night Mode
TB2-1
TB2-3
TB2-5
TB1-5
M1 Power Close Module Control Output
Dark = Power Close Active
TB1-8
OHP1 and OHP Data
Dark = Door open
TB3-4
DM1 Stall
Dark = Detecting
TB3-8 and TB4-8 Safety
Dark = Detecting
TB3-9
Breakout / M2 Power Close Monitoring
Dark = No breakout
TB4-4 and TB4-9 Operate Sensor Input and Push Plate Input (connected internally)
Dark = Detecting
TB5-3
DM1 Activation
Dark = Detecting
TB5-7
Non-Monitored Photobeam / M1 Power Close Monitoring
Dark = Detecting
TB5-10
Electric Strike
Dark = On
TB6-3
Power Close Cancel and Power Assist
at Closed Mode / DM2 Stall
Dark = On
TB6-5
DM1 and OHP1 Test
Dark = Normal
TB6-7
DM2 and OHP2 Test
Dark = Normal