T15e Tag Deployment & User Guide
40
b.
Temperature & Alarm Settings:
Local Alarm: The Local Alarm includes 3 components; Buzzer,
Alert LED and the on-screen Bell icon. These are all triggered if
the configured temperature values are out of range. By default
the (in UD mode) Local Alarm is ‘On’, and can be turned ‘Off’ by
toggling the button.
Note:
The buzzer will continue to sound unless muted on the tag
itself.
Min & Max Temperature Thresholds: Set the minimum and
maximum temperature threshold values. The tag’s Local Alarm
will be triggered when a value is out of its configured range.
Alarm Delay Period: Select the time period that a tag’s value
must be out of a configured range before an alarm is triggered.
For example; if the alarm delay period is set to 5 minutes and the
tag’s value is out of its configured range, the alarm will only be
triggered if its value does not normalize within the set time of 5
minutes.
Note:
The tag will immediately move out of alarm mode when
the temperature is back within the configured limits.
10.
To Save, Load or Export a configuration, tap the Options
icon.
11.
Tap the Apply
icon to apply the new configuration.
12.
Ensure all tag configurations are successful and then tap Done.