Makesure that the gas pipe does not pass near hot areasand that it is not exposed to possibletractions, torsions
or crushing.
The gas supply pipe (rigid or flexible) must comply with current national regulations and, in addition, must un-
dergo appropriate periodic inspections, as well as be replaced if necessary.
3.6.
Connection for flue gas evacuation
The gases resulting from the combustion of the gas must be evacuated to the outside by installing a chimney with natural draft,
or by placing the oven under an extraction hood.
Type evacuationB23:
by this way,the combustion gases are evacuated to the outside through a natural draft chimney provided
with a non-return valve. The installation must have a minimum ascending slope of 10% and, in case there are curved sections,
they must be trolleyried out at angles not less than 90 °.The first section of the installation must be straight and vertical, with a
length not less than 1m. The section of the pipe must be the same throughout the installation, and must not be provided with
sections with a lower section than the connection of the discharge pipe. If there is a need to install a horizontal section, it should
not exceed 1.5m.
O
D
O
D
It is advisable to install acapatthe endof the chimneyin order to prevent rainwater from entering the device and
prevent possible air returns causedby strong wind.
The temperature of the flue gasescanreach 500 °, so werecommend using stainless steel pipe or similar material
resistant to high temperature.
Type evacuation A3:
by this way, the flue gases are evacuated to the outside through a suction hood. The minimum distance to
keep between the oven and the hood will be at least 50cm.