4. Relay board tests.
• Disconnect the main cable from relay board J1 terminal.
• With power on, place jumper across GND/BLK and RLY/RED test points.
o
Relay
LED
should light. If not, replace lower PCB board (SM23545).
• With power on, place jumper /WHT and FLD/BRN test points.
o
Field
LED
should light. If not, replace lower PCB board (SM23545).
●
Disconnect the black W-2 ground wire. With power on
now, place a jumper on the +/WHT test point and with the
other end touch the ALT/C test point, then jump the +/WHT to the FLD/NC test point, and then jump the =/WHT to
the RES/NO test point. Once the test is completed, re
-attach the black W-2 ground wire a
nd the J
-1 main cable
socket which was removed at the beginning of the relay board test .
o
Field
LED
should light. If not, replace lower PCB board (SM23545).
Last revised 10/5/15