BAST_
02.FM
29
9 Technical data
9.5.2 M1ax. length of supply cable
* Allocation to chain hoists see "Motor data" table
*1 Voltage drop 2.5%
*2 Voltage drop 1.5%
*3 Voltage drop 5.0%
*4 Voltage drop 4.0%
Direct control
60 Hz
Max. cable length with direct control [m]
Chain hoist
Stationary *1
With trolley along runway *2
Connecting cable cross-section
1.5 mm²
2.5 mm²
1.5 mm²
2.5 mm²
230 V
400 V
460 V
230 V
400 V
460 V
230 V
400 V
460 V
230 V
400 V
460 V
Hoist motor
type
*
2A04
2/8A04
2E21
8/2E21
14
16
44
48
58
64
24
27
73
80
97
106
9
10
26
29
35
38
14
16
44
48
58
64
2E22
8/2E22
12
12
30
36
39
48
20
20
49
61
65
80
7
7
18
22
23
29
12
12
30
36
39
48
2E31
8/2E31
10
10
30
30
40
40
16
16
50
50
66
66
6
6
18
18
24
24
10
10
30
30
40
40
Contactor control
60 Hz
Max. cable length with contactor control [m]
Chain hoist
Stationary *3
With trolley along runway *4
Connecting cable cross-section
1.5 mm²
2.5 mm²
1.5 mm²
2.5 mm²
400 V
460 V
575 V
400 V
460 V
575 V
400 V
460 V
575 V
400 V
460 V
575 V
Hoist motor type
*
2A04
8/2A04
113
340
531
-
-
-
71
214
334
118
-
-
2E21
8/2E21
36
40
109
122
170
190
60
67
181
203
283
317
27
29
81
89
126
139
44
49
134
148
210
231
2E22
8/2E22
27
30
81
90
112
141
45
50
135
150
121
234
20
22
61
67
96
104
34
37
102
111
159
174
2E31
8/2E31
24
24
73
73
113
114
40
40
121
122
189
190
18
18
55
55
86
86
30
30
91
91
143
142
2E32
8/2E32
-
15
45
45
60
70
21
25
75
75
99
117
-
11
34
34
46
54
16
19
57
57
77
90
2E40
8/2E40
-
15
45
45
62
71
22
25
66
76
103
118
-
12
31
35
48
55
17
19
58
58
80
91
2E42
8/2E42
-
-
32
36
50
56
18
20
54
60
93
93
-
-
25
28
43
43
14
15
42
46
72
72
11.05