Emergency Luminaire with LED
Series EXLUX 6409/4
For further technical data, see www.r-stahl.com.
Through wiring
Assembly
Control gear
Emergency light
mode
In case of power failure the LEDs are supplied by the battery
Rated operating time at optimal ambient temperature of the battery:
Switchover voltage
From mains to battery operation at U < 0.83 x U
N
From battery to mains operation at U > 0.88 x U
N
Battery set
Version
NiCd battery, gas-tight
Operating voltage
6 V
Capacity
7 Ah
Replacing the
battery set
When opening the battery enclosure, the connection between the battery
and the control gear is disconnected by means of a switch.
The battery set can be replaced after disconnecting the plug-in contacts.
Optional
DALI-connection
DALI interface in accordance with IEC 62386-207:2009-08
Breather
Breather 8162/1 from R.STAHL Schaltgeräte GmbH
The breather guarantees compliance with degree of protection IP64
in all mounting positions. The breather may not be used in atmospheres
with corrosive gasses.
Technical Data
Standard
luminaire
with
Luminaries are equipped with internal through wiring.
Connection of ingoing and outgoing leads on
opposite sites is possible.
Terminals: See Tech. data
Wiring cross section of the supply line connection:
2.5 mm
2
for max. 16 A
(Observe service temperature)
Optional
without
On the connection side, there are 2 bores M25 x 1.5
for cable entries for ingoing and outgoing wiring of the
connection line
(ingoing and outgoing leads on one side).
Standard luminaire
Standard:
2 x M8 insert nuts in the enclosure
Special:
Mounting grooves in the enclosure for use of fastening
and ceiling rails for variable luminaire mounting
(variable mounting distances for luminaires
L = 700 mm: 320 to 480 mm;
L = 1310 mm; 670 to 930 mm)
Battery
capacity
Rated operating
time
Emergency light output
Size 2
Size 4
7 Ah
1.5 h
65 %
35 %
3.0 h
35 %
20 %