Programming 

The firing segment 

The ST312 firing segment comprises 2 ramps followed by a soak period.  
This single segment can be used for simple firing (biscuit firing for exam-
ple). 
 
The ST312 ramps the kiln temperature at ramp rate 1 until the kiln reaches 
temperature t1.  It then ramps the kiln temperature to the soak temperature 
at ramp rate 2.  It then soaks (dwells) at the soak temperature for the soak 
time.  It then allows the kiln to cool naturally. 
 
The ST312 is capable of both positive (heating) ramps and negative 
(cooling) ramps—as used in glassmaking for annealing. 
 
Ramp rate 1 & ramp rate 2 are settable in the range 1°C/hour to 999°C/
hour or 

FULL 

(full power) or 

End 

(end of program). 

 
t1 & the soak temperature are settable over the range 0 to 1320°C. 
 
The soak time is settable over the range 00.00 (no soak) to 99 hours 59 
mins. 

Note: during soaking the ST312 display alternates every 5 seconds 
between kiln temperature and soak time remaining. 

Pr

ogramming 

t1 

soak temperature 

ra

m

ra

te

 1

 

ra

m

p

 r

at

2

 

soak period 

ST312 User Handbook 

 

 

 

 

       Page   15 

Program Pause Facility 

While firing press and hold down the  

ª

 key for about 4 seconds.  The 

ST312 will pause the executing program.  To un-pause the program press 
and hold down the the  

ª

 key again for about 4 seconds.  The effects of 

pausing are as follows:- 
 
If paused during a ramp the kiln temperature will be held (soaked) 

indefi-

nitely

 at the current kiln temperature.  The ramp will continue when un-

pause is selected. 
 
If paused during a soak then the soak time will be 

extended indefinitely

.  

The remainder of the soak period will be resumed when un-pause is se-
lected. 
 
Segment advance (

©

 key held down for about 4 seconds) can also be used 

to terminate the pause.  This will advance the segment and will immedi-
ately terminate a paused soak and end the firing program. 
 
Changes made to the operation of the ST312 in this way are temporary 
and are not stored. 

 PAUSED

 

 600

 

°C 

°C/hr 

hr.min 

As a warning during pause a double 
beep is sounded every 10 seconds, 
the display scrolls 

PAUSed

 for 5 

seconds then shows the kiln tem-
perature for 5 seconds. 

Adjusting While 

Firing 

WARNING - PROGRAM PAUSE 
The program pause facility should be used with care.  Program execution is 
suspended and the kiln will be held at its current temperature indefinitely.   
 
If left too long at high temperatures kiln damage could result. 

Summary of Contents for ST312

Page 1: ...ser Handbook Page 1 ST312 User Handbook STAFFOR D INSTRUMENTS Stafford Instruments Ltd Tel 44 0 1785 255588 Fax 44 0 1785 255589 www stafford inst co uk email support stafford inst co uk Issue 1 002 D...

Page 2: ...Low Temperature Glaze 90 C hr 600 C 00 30 Earthenware Mid Temperature Glaze 90 C hr 600 C 00 30 Earthenware High Temperature Glaze 90 C hr 600 C 00 30 Stoneware Glaze 90 C hr 600 C 00 30 On Glaze Enam...

Page 3: ...not locked Press and hold in both the keys for 5 seconds to lock the ST312 Power Failure Recovery If power fails during firing then the ST312 recovers as follows For power failure during start delay t...

Page 4: ...312 to terminate the firing with all the keys locked An alarm buzzer sounds once per second SWITCH KILN OFF To reset the ST312 turn off the power to the instrument and have the fault investigated by y...

Page 5: ...99 hours limit Err6 C C hr hr min Possible causes are contactor failure or thermocouple connection intermittent or high resistance ST312 User Handbook Page 5 Turning On F1 04 tC r tC S tC n tC K 8 8 8...

Page 6: ...am Pause Facility While firing press and hold down the key for about 4 seconds The ST312 will pause the executing program To un pause the program press and hold down the the key again for about 4 seco...

Page 7: ...rature If currently soaking then the ST312 will end the firing Changes made to the operation of the ST312 in this way are temporary and are not stored Adjusting While Firing ST312 User Handbook Page 7...

Page 8: ...through the programming steps to correct errors or to exit programming mode Note available ramp rate displays are End 1 999 FULL If End is shown but another segment is required then push the key to ob...

Page 9: ...ture can be disabled see in stallation handbook Firing Delayed Start The delayed start time period is set to 00 00 when the ST312 is turned on ST312 User Handbook Page 9 Firing To start a firing press...

Page 10: ...Page ST312 User Handbook 10 Program Record Sheet Ramp 1 C hr t1 C Ramp 2 C hr Soak Temp C Soak Time hr min Please photocopy me ST312 User Handbook Page 11 Program Description Please photocopy me...