background image

Page 

     ST312 

User 

Handbook 

18 

Other Features 

Energy Used Display 

Pressing the 

§

 button at any time shows the amount of electrical energy used 

in kW hours.  If pressed during a firing it shows the energy used so far.  After 
a firing it shows the total energy used for that firing.  This information is 
stored while power is off and is only reset to zero when a new firing is 
started. 
 
If the value displayed is always 

0

.

0

 then the kiln power rating has not been 

configured into the ST312—see installation handbook. 

Keyboard Lock Facility 

1

.

200

 

°C 
°C/hr 
hr.min 

The keys on the ST312 can be locked so that pressing them has no effect.  
This is an anti-tamper feature used to ensure that the operation of the ST312 
or the program data cannot be altered by un-authorised people.  The ST312 
can be locked when it is idle (not firing) or while it is firing.  It cannot be 
locked while it is being programmed. 

If the left-hand decimal point in the 
display is lit then the ST312 is locked.  
Press and hold in both the 

©

 & 

ª

 keys  

for 5 seconds to unlock the ST312. 

1200

 

°C 
°C/hr 
hr.min 

If the left-hand decimal point in the dis-
play is not lit then the ST312 is not 
locked.  Press and hold in both the 

©

 & 

ª

 keys  for 5 seconds to lock the ST312. 

Power Failure Recovery 

If power fails during firing then the ST312 recovers as follows:- 
For power failure during start delay the ST312 commences firing immedi-
ately when power returns.  For power failure during ramp 1 or ramp 2 the 
ST312 goes back into the ramp it was previously executing.  For power fail-
ure during soaking the ST312 ramps back up to soak temperature at ramp 
rate 2 then applies the full soak period.  This recovery scheme can be dis-
abled if required (see installation handbook) - the ST312 will then lock up 
with 

FAIL

 displayed and kiln off in the event of power failure. 

Other

 Featur

es 

ST312 User Handbook 

 

 

 

 

       Page   3 

Quick S

tart Guide 

Quick Start Guide 

Switch on & wait for kiln temperature display

 

To run a firing program set up previously press the 
START/STOP key

 

To stop the firing at any time press the START/
STOP key again

 

To review firing data press the 

¨

 key to enter the 

programming menu

 

To change firing data press the 

©

 & 

ª

 keys to 

change the displayed value

 

Use the 

¨

 key again as necessary to index to the 

next firing value to be reviewed or changed

 

To exit the programming menu either wait 10 sec-
onds or press the START/STOP key to start firing 

If the keyboard is locked then press the 

©

 & 

ª

 keys 

together & hold down for 5 seconds to unlock

 

Summary of Contents for ST312

Page 1: ...ser Handbook Page 1 ST312 User Handbook STAFFOR D INSTRUMENTS Stafford Instruments Ltd Tel 44 0 1785 255588 Fax 44 0 1785 255589 www stafford inst co uk email support stafford inst co uk Issue 1 002 D...

Page 2: ...Low Temperature Glaze 90 C hr 600 C 00 30 Earthenware Mid Temperature Glaze 90 C hr 600 C 00 30 Earthenware High Temperature Glaze 90 C hr 600 C 00 30 Stoneware Glaze 90 C hr 600 C 00 30 On Glaze Enam...

Page 3: ...not locked Press and hold in both the keys for 5 seconds to lock the ST312 Power Failure Recovery If power fails during firing then the ST312 recovers as follows For power failure during start delay t...

Page 4: ...312 to terminate the firing with all the keys locked An alarm buzzer sounds once per second SWITCH KILN OFF To reset the ST312 turn off the power to the instrument and have the fault investigated by y...

Page 5: ...99 hours limit Err6 C C hr hr min Possible causes are contactor failure or thermocouple connection intermittent or high resistance ST312 User Handbook Page 5 Turning On F1 04 tC r tC S tC n tC K 8 8 8...

Page 6: ...am Pause Facility While firing press and hold down the key for about 4 seconds The ST312 will pause the executing program To un pause the program press and hold down the the key again for about 4 seco...

Page 7: ...rature If currently soaking then the ST312 will end the firing Changes made to the operation of the ST312 in this way are temporary and are not stored Adjusting While Firing ST312 User Handbook Page 7...

Page 8: ...through the programming steps to correct errors or to exit programming mode Note available ramp rate displays are End 1 999 FULL If End is shown but another segment is required then push the key to ob...

Page 9: ...ture can be disabled see in stallation handbook Firing Delayed Start The delayed start time period is set to 00 00 when the ST312 is turned on ST312 User Handbook Page 9 Firing To start a firing press...

Page 10: ...Page ST312 User Handbook 10 Program Record Sheet Ramp 1 C hr t1 C Ramp 2 C hr Soak Temp C Soak Time hr min Please photocopy me ST312 User Handbook Page 11 Program Description Please photocopy me...