Adjusting While Firing 

Firing values can be adjusted while the ST312 is firing.  Also there are 
program pause/un-pause and segment advance features that are particulary 
useful for glass work. 

Adjusting Firing Values 

While firing operate the 

¨

 key to select the required parameter as shown by 

a flashing lamp on the mimic display.  The firing value is shown on the main 
display and can now be adjusted with the 

©

 & 

ª

 keys in the usual way.  

Firing will still carry on as normal while these changes are being made.  The 
ST312 will return to its normal running display 10 seconds after key presses 
cease (or immediately after 

End

 is displayed). 

 
Changes made to the program in this way are stored and are used for 
subsequent firings. 

Segment Advance Facility 

While firing press and hold down the  

©

 key for about 4 seconds.  The 

ST312 will sound a short beep and the executing program will immedi-
ately advance one step as indicated by lamps on the mimic panel.  The 
effect of this is as follows:- 
 
If a start delay is currently executing then the ST312 will terminate this 
and start firing immediately. 
 
If ramp 1 segment is currently executing then the ST312 will switch to 
ramp 2 using ramp rate 2 from the current kiln temperature. 
 
If ramp 2 segment is currently executing then the ST312 will switch to 
soak at the current kiln temperature. 
 
If currently soaking then the ST312 will end the firing. 
 
Changes made to the operation of the ST312 in this way are temporary 
and are not stored. 

Adjusting While 

Firing 

ST312 User Handbook 

 

 

 

 

       Page   7 

When the ST312 is not firing there are no lamps lit on the mimic panel, 
the run lamp is off and the display shows the kiln temperature with the °C 
indicator lit. 

Altering the program 

 

.

 20

 

°C 
°C/hr 
hr.min 

If the left-hand decimal point is on 
then the keyboard is locked.  Press 
the 

©

 & 

ª

 keys together & hold 

down for 5 seconds to unlock. 

The controller settings can be reviewed by pressing the 

¨

 key. 

Note: holding down the 

©

 or 

ª

 keys causes rapid change of the displayed 

value. 

00

.

00

 

°C 
°C/hr 
hr.min 

The first push of the 

¨

 key displays 

the start delay time in the range 00.00 
to 99.59 (99 hours 59 mins).  This 
can be altered with the 

©

 & 

ª

 keys.  

The DELAYED START lamp on the 
mimic display will flash. 

  50

 

°C 
°C/hr 
hr.min 

¨

 then displays ramp rate 1 in the 

range 1 to 999°C/hr or 

FULL

 or 

End

.  

This can be altered with the 

©

 & 

ª

 

keys.  RAMP 1 lamp on the mimic 
display will flash. 

 600

 

°C 
°C/hr 
hr.min 

¨

 then displays temperature t1 in the 

range 0 to 1320°C.  This can be 
altered with the 

©

 & 

ª

 keys.  The t1 

lamp on the mimic display will flash. 

 250

 

°C 
°C/hr 
hr.min 

¨

 then displays ramp rate 2 in the 

range 1 to 999°C/hr or 

FULL

 or 

End

.  

This can be altered with the 

©

 & 

ª

 

keys.  The RAMP 2 lamp on the 
mimic display will flash. 

1250

 

°C 
°C/hr 
hr.min 

¨

 then displays the soak temperature 

in the range 0 to 1320°C.  This can be 
altered with the 

©

 & 

ª

 keys.  The 

SOAK TEMPERATURE lamp on the 
mimic display will flash. 

Pr

ogramming 

Summary of Contents for ST312

Page 1: ...ser Handbook Page 1 ST312 User Handbook STAFFOR D INSTRUMENTS Stafford Instruments Ltd Tel 44 0 1785 255588 Fax 44 0 1785 255589 www stafford inst co uk email support stafford inst co uk Issue 1 002 D...

Page 2: ...Low Temperature Glaze 90 C hr 600 C 00 30 Earthenware Mid Temperature Glaze 90 C hr 600 C 00 30 Earthenware High Temperature Glaze 90 C hr 600 C 00 30 Stoneware Glaze 90 C hr 600 C 00 30 On Glaze Enam...

Page 3: ...not locked Press and hold in both the keys for 5 seconds to lock the ST312 Power Failure Recovery If power fails during firing then the ST312 recovers as follows For power failure during start delay t...

Page 4: ...312 to terminate the firing with all the keys locked An alarm buzzer sounds once per second SWITCH KILN OFF To reset the ST312 turn off the power to the instrument and have the fault investigated by y...

Page 5: ...99 hours limit Err6 C C hr hr min Possible causes are contactor failure or thermocouple connection intermittent or high resistance ST312 User Handbook Page 5 Turning On F1 04 tC r tC S tC n tC K 8 8 8...

Page 6: ...am Pause Facility While firing press and hold down the key for about 4 seconds The ST312 will pause the executing program To un pause the program press and hold down the the key again for about 4 seco...

Page 7: ...rature If currently soaking then the ST312 will end the firing Changes made to the operation of the ST312 in this way are temporary and are not stored Adjusting While Firing ST312 User Handbook Page 7...

Page 8: ...through the programming steps to correct errors or to exit programming mode Note available ramp rate displays are End 1 999 FULL If End is shown but another segment is required then push the key to ob...

Page 9: ...ture can be disabled see in stallation handbook Firing Delayed Start The delayed start time period is set to 00 00 when the ST312 is turned on ST312 User Handbook Page 9 Firing To start a firing press...

Page 10: ...Page ST312 User Handbook 10 Program Record Sheet Ramp 1 C hr t1 C Ramp 2 C hr Soak Temp C Soak Time hr min Please photocopy me ST312 User Handbook Page 11 Program Description Please photocopy me...

Reviews: