L6482
Programming manual
Doc ID 023768 Rev 1
55/73
The TCC parameter defines the deadtime duration between the gate turn-off and the
opposite gate turn-on sequences (
The TBLANK parameter defines the duration of the blanking of the current sensing
comparators (stall detection and overcurrent) after each commutation (
9.1.20 CONFIG
The CONFIG register has the following structure:
The OSC_SEL and EXT_CLK bits set the system clock source:
Table 32.
TDT parameter
TDT [4..0]
Deadtime [ns]
0
0
0
0
0
125
0
0
0
0
1
250
⇓
⇓
⇓
⇓
⇓
⇓
1
1
1
1
0
3875
1
1
1
1
1
4000
Table 33.
TBLANK parameters
TBLANK [2..0]
Blanking time [ns]
0
0
0
125
0
0
1
250
⇓
⇓
⇓
⇓
1
1
0
875
1
1
1
1000
Table 34.
CONFIG register
Bit 15
Bit 14
Bit 13
Bit 12
Bit 11
Bit 10
Bit 9
Bit 8
PRED_E
TSW
VCCVAL UVLOVAL
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
OC_SD
RESERVED
EN_TQREG
SW_MOD
E
EXT_CLK
OSC_SEL