Programming manual
L6482
48/73
Doc ID 023768 Rev 1
9.1.11 T_FAST
The T_FAST register contains the maximum fast decay time (TOFF_FAST) and the
maximum fall step time (FALL_STEP) used by the current control system (
for details):
The available range for both parameters is from 0.5 µs to 8 µs.
Any attempt to write to the register when the motor is running causes the command to be
ignored and NOTPERF_CMD to rise (
9.1.12 TON_MIN
This parameter is used by the current control system when current mode operation is
selected.
The TON_MIN register contains the minimum on-time value used by the current control
system (see
The available range for both parameters is from 0.5 µs to 64 µs.
Table 15.
Torque regulation by TVAL_HOLD, TVAL_ACC, TVAL_DEC and
TVAL_RUN registers
TVAL_X [6..0]
Output current amplitude
0
0
0
0
0
0
0
7.8 mV
0
0
0
0
0
0
1
15.6 mV
…
…
…
…
…
…
…
…
1
1
1
1
1
1
0
992.2 mV
1
1
1
1
1
1
1
1 V
Table 16.
FS_SPD register
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
TOFF_FAST FAST_STEP
Table 17.
Maximum fast decay times
TOFF_FAST [3..0] FAST_STEP[3..0]
Fast decay time
0 0 0 0
0.5
µs
0 0 0 1
1
µs
…
…
…
…
…
1 1 1 0
7.5
µs
1 1 1 1
8
µs