Caution
INSTALLATION IS TO BE PERFORMED BY A QUALIFIED INSTALLER OR
DEALER.
ADHERE TO ALL CLEARANCES SPECIFIED BY THE MANUFACTURER OF THE
VENTING SYSTEM USED.
ADHERE
TO
ALL
CLEARANCES
SPECIFIED
IN
THE
INSTALLATION
INSTRUCTIONS OF THE ELEMENT-P STOVE.
THE ELEMENT-P STOVE USES A POSITIVE PRESSURE VENT SYSTEM. DO NOT
INSTALL A FLUE DAMPER IN THE EXHAUST SYSTEM OF UNIT
DO NOT CONNECT THE ELEMENT-P STOVE TO A CHIMNEY SYSTEM THAT IS
CONNECTED TO ANOTHER APPLIANCE.
DO NOT INSTALL THIS UNIT IN A SLEEPING ROOM
ATTENTION
CONDENSATION:
When planning the installation of your Element-P
Stove, keep in mind that condensation is detrimental to exhaust systems. Corn
has higher moisture content than pellets and can be more susceptible to
condensation forming in certain installations. Install the Element-P with a
minimum of the Vent system exposed to the cold temperatures outside the
envelope of the house. Insulate the vent system if in doubt. Check with the
manufacturer of your venting system that they honor the warranty of their PL
Vent with the use of corn.
ATTENTION
BATTERY BACKUP: We strongly recommend using a battery backup system if
the Element-P is installed using horizontal venting only. This prevents any
smoke from entering your home in the event of a power failure. The battery
back-up system must provide “pure sine wave” power to operate the unit.
Summary of Contents for Element-P
Page 51: ...Element P 51 PARTS LAYOUT Figure 34 ...
Page 52: ...Element P 52 Figure 35 PARTS LAYOUT ...
Page 53: ...Element P 53 PARTS LAYOUT Figure 36 ...
Page 54: ...Element P 54 PARTS LAYOUT Figure 37 Figure 38 ...
Page 55: ...Element P 55 Sensor System Figure 39 Versa Grate Motor Assembly Figure 40 Figure 41 ...
Page 56: ...Element P 56 Figure 42 ...