Element-P
17
Hearth Mount
Legend
A – Vertical Cap
B – Chimney Flashing
C – Positive Block Off Plate
D – Stainless Steel Liner / PL Vent System
E – PL Tee or Single Wall Tee
F – Outside Air Shield – May be needed
G – 2” Metal Outside Air Pipe - Optional
Figure 9
Venting to the Top of Chimney
When installing as a hearth mount stove into a fireplace, the unit must either be relined
terminating above the chimney chase top, or positively connected to the existing chimney
system using a block off plate (C). An approved flex liner or PL vent must be used.
A
chimney system with known drafting problems may require a liner, which may also
need to be insulated to keep vent system warm in a cold chimney environment.
Summary of Contents for Element-P
Page 51: ...Element P 51 PARTS LAYOUT Figure 34 ...
Page 52: ...Element P 52 Figure 35 PARTS LAYOUT ...
Page 53: ...Element P 53 PARTS LAYOUT Figure 36 ...
Page 54: ...Element P 54 PARTS LAYOUT Figure 37 Figure 38 ...
Page 55: ...Element P 55 Sensor System Figure 39 Versa Grate Motor Assembly Figure 40 Figure 41 ...
Page 56: ...Element P 56 Figure 42 ...