Element-P
32
c.
The Igniter and the Auger come on (the Auger runs continuously for 1 minute,
then switches to #1 feed rate). The stove will typically light in the first 3 - 4
minutes. After 5 minutes the board checks for “Proof of Fire”. Once the board
senses P.O.F. the Igniter shuts off and the stove has started successfully.
d.
If the board fails to sense P.O.F. it will repeat the previous step and continue
feeding pellets on the #1 setting for 5 more minutes.
e.
The board will check for P.O.F. one more time. If the board still fails to sense the
Proof of Fire switch, the stove will go into “Safety shutdown” (See Diagnostic
Features on page 33 through 35)
If the stove fails to start, repeat steps listed above.
CAUTION: NEVER ADD FIRE STARTER TO A HOT STOVE.
Shutting the Unit Off
1. Press the On/Off switch once; the lights will go off and the fire will go out in a few
minutes. The board essentially goes into “Safety shutdown”.
2.
As long as the temperature within the Element-P remains above 110°F both Fans will
continue to run. When the P.O.F. switch drops out, the room fan shuts off and the
Combustion fan will run for another 10 minutes and finally shut down completely.
3.
NEVER unplug the Stove to shut it off. Doing so may cause a significant amount of
smoke to enter the room.
Summary of Contents for Element-P
Page 51: ...Element P 51 PARTS LAYOUT Figure 34 ...
Page 52: ...Element P 52 Figure 35 PARTS LAYOUT ...
Page 53: ...Element P 53 PARTS LAYOUT Figure 36 ...
Page 54: ...Element P 54 PARTS LAYOUT Figure 37 Figure 38 ...
Page 55: ...Element P 55 Sensor System Figure 39 Versa Grate Motor Assembly Figure 40 Figure 41 ...
Page 56: ...Element P 56 Figure 42 ...