Element-P
29
3. The Heat Level button changes the Heat Level up and down between level 1 and 5. It
will also be used in the Fine Tuning process of the feed rates if needed.
To adjust the Feed-rates:
Press and hold the Auger Feed Button, then press the Heat Level High
or
Low button.
This will change the ON Time
up or down
.25 seconds from the factory setting. Watch
the LED lights to see the setting is on (it will flash the new setting). This new setting will
stay in memory. The LED lights indicate the level of adjustment. The factory setting is
the center LED light. This gives two .25 second adjustments up and two .25 second
adjustments down.
4. The Trim button is used to adjust the Exhaust (Combustion) fan voltages up or down
to allow
fine-tuning
of the combustion air. The LED lights indicate the level of
adjustment. The factory setting is the center LED light. This gives 2 adjustments up and 2
adjustments down.
To adjust the Combustion Fan voltages:
Press and hold the Auger Feed button, then press the Trim High
or
Low button. This will
change the fan voltage approximately 2.5 volts up or down from the factory setting.
Watch the LED lights to see the setting is on (it will flash the new setting). This new
setting will stay in memory from this point on.
Use these adjustments in conjunction
with the damper.
5. The Thermostat Slide switch allows the Stove to be run in 3 different Modes:
a.
Manual Mode
. The Control Board controls all functions of the Element-P.
b.
T-Stat Mode
.
The Stove is Fully-Automatic in the T-Stat Mode.
(T-Stat requires the
stove be turned on at the control board the first time).
The Stove is Fully Automatic in
the T-Stat Mode.
The unit is hooked to a Thermostat and when calling for heat the
Element-P will advance to the Heat level set at the Control board. Once the Heat
demand has been met, the Stove will immediately shut down. Use this setting when
heating a small area or when Temperatures are Moderate.
Not recommended for use
with a mixture of Pellets and Corn.
c.
SmartStat Mode
. The unit is hooked to a Thermostat and when calling for heat the
Stove will advance to the Heat level set at the Control board. Once the Heat demand
has been met the Stove will drop to the #1 Heat Level setting
and pilot for one hour
.
If the Thermostat does not call for heat during that hour, the unit shuts off and
re-
lights itself the next time the Thermostat calls for heat
. This setting is best used
when constant heat is needed.
Not recommended for use with a mixture of Pellets and
Corn.
6.
Cleaning Cycle.
The Element-P only uses Programs 3 & 4. This allows the
Element-P to operate in an Automatic mode using the Igniter. These 2 programs have a
Cleaning Cycle built into them that allows
the unit to drop to the #1 level for 5 minutes
on timed intervals. During the cleaning cycle the Combustion Fan will run at line voltage
to blow excess ash from the burn pot. This feature only functions if the unit is operating
on levels 3 through 5.
The ON/OFF light blinks during this cycle
.
Summary of Contents for Element-P
Page 51: ...Element P 51 PARTS LAYOUT Figure 34 ...
Page 52: ...Element P 52 Figure 35 PARTS LAYOUT ...
Page 53: ...Element P 53 PARTS LAYOUT Figure 36 ...
Page 54: ...Element P 54 PARTS LAYOUT Figure 37 Figure 38 ...
Page 55: ...Element P 55 Sensor System Figure 39 Versa Grate Motor Assembly Figure 40 Figure 41 ...
Page 56: ...Element P 56 Figure 42 ...