3 – 16
Remote Operation
Stop Streaming
SOUT [
z
]
Turn o
ff
streaming (of channel
z
=
(
SMN 0
,
MMN 1
,
EMN 2
,
OMN 3
)).
If the optional parameter
z
is not specified, then all streaming outputs
are turned o
ff
.
SOUT
Example:
Frequency of Power Line Cycle
FPLC(?)
{
i
}
Set (query) the power line cycle frequency
{
to
i
=
(
50
,
60
)
}
Hz.
FPLC
is used to program the power-line rejection frequency for the
precision voltage monitors (
SMON?
,
MMON?
,
EMON?
,
OMON?
).
FPLC?
Example:
60
3.4.6
Display commands
Select Field
DISP(?)
{
z
}
Set (query) the field level to be displayed
{
to
z
}
. Allowed values of
z
are
PRP 0
Proportional gain
IGL 1
Integral gain
DER 2
Derivative gain
OFS 3
Output o
ff
set
RTE 4
Setpoint rate
STP 5
Setpoint value
MNL 6
Manual output value
ULM 7
Upper limit of output
LLM 8
Lower limit of output
SMN 9
ADC measurement of Setpoint input
MMN 10
ADC measurement of Measure input
EMN 11
ADC measurement of P-Amplified error
OMN 12
ADC measurement of PID
/
Manual Output
DISP 1
Example:
Shift Status
SHFT(?)
{
z
}
Set (query) the current shift status
{
to
i
=
(
OFF 0
,
ON 1
)
}
.
SHFT?
Example:
OFF
SIM960 Analog PID Controller