SMART CELLAR INVERTER COOLING UNIT
CAUTION
• SMART CELLAR ultra compact indoor unit and SMART CELLAR inverter outdoor unit must be
installed on the same circuit breaker.
1. Remove the cover of the electric box of the indoor unit.
2. Insert the power cable through the rubber ring.
3. Connect the wiring (communication) through the piping hole of the chassis and upward
through the bottom of the appliance
4. Connect the brown wire to the Terminal board “3”; black wire (the communication wire) to the
Terminal board “2”; blue wire to the Terminal board “N(1)”,and connect the earthing wire to the
screw terminal on the electric box. Clamp them with the corresponding wire clamp packed in
the chassis.
5. Fix the power cable tightly with the binding wire.
6. Connect transformer interface cable to mains power supply at indoor unit location.
Wiring Of The Field Supplied 24V Thermostat And Communication Cable From Outdoor Unit
●
Wall mount your smart thermostat
●
Connect corresponding terminals from your smart thermostat to SMART CELLAR ULTRA
COMPACT indoor unit 24V terminal strip
●
Power on SMART CELLAR system
●
Set up your smart thermostat according to the manufacturer's instructions.
●
After your smart thermostat is powered up, Select cool mode and adjust your set point
temperature.
SMART
CELLAR
R +24V AC
C - 24V AC
Y1 COOL/
COMP
Y2 COOL/
COMP
WWW.AIRSHEPHERD.COM.AU