Figure 8- Suggested Media Piping, Steam
S
PI
TC
TY
TE
PI
PI
1
2
4
3
5
6
7
9
8
10
11
12
HE100-056
Waukesha Cherry-Burrell
Installation
11/2012
95-03057
Page 13
Suggested Media Piping
for Water or Liquid
The media piping should flow counter-current to the product flow,
and should be circulating at a rate of 50 gpm. The suggested
arrangement automates the source flow to the actual heat
exchange requirements to provide maximum control of the
process.
Figure 9 - Suggested Media Piping, Water or Liquid
TC
TY
TE
TI
TI
PI
MS
TI
PI
TI
1
2
3
4
5
6
7
HE100-057
Table 1: Call Outs For Figure 8
1. Steam IN
2. Strainer
3. By-Pass Line
4. Steam Pressure Regulator
5. Steam Solenoid
6. Temperature Regulator
7. I/P
8. Temperature Control
9. Product OUT
10. Product IN
11. Drain Valve
12. Condensate Trap
Table 2: Call Outs For Figure 9
1. Media IN
2. Product OUT
3. Product IN
4. Temperature Regulator
5. Media OUT
6. I/P
7. Temperature Control