ZOOM 300 User manual Revision 03 January 2015 

 

3.5.6.1  ZOOM300 Status 

 

ZOOM300 Status 

Functions 

 

   

 
This  page  checks  and  displays  whether  the 
hardware  components  inside  the  scanner  are 
correctly powered and running. 
 
The  components  that  are  working  properly 
are marked with the initials “OK”. 
 
If  the  Status  is  other  than  “Ready”,  please 
contact  Midarex  Laser  Team  support

providing the .X3K file (see par. 3.5.6.5) 
 
 

 

 

 

 

 

 

 
 

3.5.6.2  System 

 

System 

Functions 

 

 

 

 
Allows to check:   

 

Battery level 

 

Power voltage 

 

Internal temperature 

 
 
 

 

 
 
The  battery level is also visible in the  battery 
notification  icon  located  in  the  upper‐right 
corner of the main page (red arrow). 

 
 

 
 

 

Summary of Contents for ZOOM 300

Page 1: ...User Manual Revision 03 January 2015...

Page 2: ...ARD IDENTIFICATION 11 1 11 3 FIRE FIGHTING MEASURES 11 1 11 4 ACCIDENTAL RELEASE MEASURES 11 1 11 5 TEMPERATURE RANGE 11 1 11 6 STABILITY AND REACTIVITY 11 1 11 7 TOXOLOGICAL INFORMATION 11 1 11 8 ECO...

Page 3: ...3 5 GPS OFFSETS 22 3 3 6 ZOOM300 FRAMEWORK OFFSETS OPTIONAL ACCESSORY 23 3 4 USE OF THE ONBOARD SOFTWARE 24 3 4 1 TESTED OS AND WEB BROWSERS 24 3 4 2 Connect to ZOOM300 24 3 5 WEB INTERFACE 27 3 5 1 H...

Page 4: ...which real objects are surveyed and sampled almost completely to determine their location size orientation and form The ZOOM 300 rapidly determines high resolution measurement results within very shor...

Page 5: ...2 GPS mount 3 Laser window 4 Camera window camera UP and camera DOWN 5 Power button 6 Led control bar 7 USB port 8 Smart port Ethernet and external power supply 9 GPS port 10 Battery handle 11 Batter...

Page 6: ...100 V step 100 H step 200 V step 200 Fine 0 3927 1 1781 1 9635 3 9270 7 8540 Standard 0 7854 2 3562 3 9270 7 8540 15 7080 Fast 1 5708 4 7124 7 8540 15 7080 31 4159 Preview 3 1416 9 4248 15 7080 31 41...

Page 7: ...ondition The noise from the instrument When the instrument is working it is normal if you hear noises from instrument motors They will not affect the instrument work Stored data responsibility MIDAREX...

Page 8: ...imize self discharging of the batteries 1 8 Cleaning and Drying Never touch the cover glass with your fingers Use only a clean soft lint free cloth for cleaning If necessary moisten the cloth with wat...

Page 9: ...performance like switching on off automatically and so on Do not touch the instrument with wet hand Electric shock could result Do not stand or seat on the carrying case and do not turn over the carry...

Page 10: ...E BEAM Never point the laser beam at other s eyes It could cause serious injury Never look directly into the laser beam source It could cause permanent eye damage Never stare at the laser beam It coul...

Page 11: ...ions put on adequate protective equipment Do not breath vapour Environmental precautions keep away from drains surface water ground water and soil Clean procedures collect as much as possible using cl...

Page 12: ...s keys pins or wires 1 12About User 1 This product is for professional use only The user is required to be a qualified surveyor or have a good knowledge of surveying in order to understand the user ma...

Page 13: ...g screw 3 Drive the tripod s legs firmly into the ground 4 Set up the tripod so that its plate is as horizontal as possible 5 Level the tribrach using the circular level Turn two of the leveling screw...

Page 14: ...able Figure 3 represents the ZOOM 300 battery pack for proper mounting the connectors must be facing up and the handle must be on the outer side Figure 4 represents the ZOOM 300 battery housing placed...

Page 15: ...e the battery follow the instructions described in Figure 7 and Figure 8 1 Use the handle to press down the battery until stroke end 2 Tilt the battery outward until the upper edge is out of the housi...

Page 16: ...Figure 12 3 Connect the external power unit to the power source During the charge the status light on the power pack will inform you about the charge progress Figure 13 The charging time for a complet...

Page 17: ...means that the ZOOM 300 is doing the initialization procedures Two short beeps are emitted to signal that the system controller has done its work and the microcontroller has started After a while the...

Page 18: ...on 4 After a while a series of beeps will be emitted If you release the button during this phase a Standard shutdown will occur o A short beep is emitted o A long beep is emitted o STATUS LEDs GREEN s...

Page 19: ...e in different colors Starting from the left Red Yellow Green Ten Blue LEDs in the middle are used to display the progress of long operations such as scan and saving Three LEDs on the right are dedica...

Page 20: ...Use the controller to check the failure on Status section Scan initialization ZOOM300 is busy working on something performing a scan for example ZOOM300 is storing data Scan successfully completed A n...

Page 21: ...10 one short beep every 4 seconds At 5 prolonged beep every 4 seconds 3 3 4 Internal temperature alert Temperature is continuously monitored The alarm is visible on the YELLOW Status LED Temp 15 or 7...

Page 22: ...OM 300 User manual Revision 03 January 2015 3 3 5 GPS offsets The following diagram shows the position of the origin point of the measures and the relative offsets to the GPS mount Figure 15 GPS offse...

Page 23: ...ZOOM 300 User manual Revision 03 January 2015 3 3 6 ZOOM300 Framework offsets optional accessory Figure 16 ZOOM 300 Framework offsets...

Page 24: ...browsers The ZOOM 300 web interface is based on HTML 5 markup language and it is compatible with most of the latest browsers on the market The table 6 reports the operating systems and web browsers th...

Page 25: ...January 2015 2 Search for the ZOOM300 wireless network using the OS connection manager the ZOOM300 is identified by its serial number e g Z300PSXXXXXX 3 Connect to the ZOOM300 network It is an open c...

Page 26: ...refresh the page or enter the following IP address 192 168 1 11 5 The access to the main page is protected by User ID and Password Default settings User ID ZOOM300 or Zoom300 no case sensitive Passwo...

Page 27: ...the scan procedure Files management Browse and manage stored data Camera Enter the camera settings menu and preview thumbnail Preferences Enter ZOOM300 preferences Language change interface language S...

Page 28: ...n resolution from the drop down list par 1 4 3 Horizontal angle Set the angle for the horizontal rotation of the scanner unit deg 4 Photos Enable Disable the photos capture using the ZOOM300 internal...

Page 29: ...accept the suggestion If advised name is not accepted and the invalid or existing one is not modified clicking on Start button a system message will appear asking for continuing with rename procedure...

Page 30: ...n 3 Scan Scanning in progress Use either the software progress bar on the control device or the LEDs status bar on the ZOOM300 to check the progress When the scan is finished the ZOOM300 will return t...

Page 31: ...can file in x3a format Available are Select options and tools Searching filter bar Scan details profile 1 Select button When you click on Select button little squares will appear near scan file names...

Page 32: ...f the point cloud scanned by the ZOOM300 without pictures matching b Copy to USB USB download becomes available when a USB memory drive is connected to the ZOOM300 USB port Click on Point cloud and pi...

Page 33: ...from ZOOM300 internal memory NOTE Deleted files are permanently removed from the ZOOM300 solid memory e Information This panel shows the details of the scan file Scan mode preview fast standard fine H...

Page 34: ...on Press the Take a shot button to acquire a picture preview from the selected camera Camera up the upper camera facing forward Camera down the lower camera facing upward Manual exposure Enter manuall...

Page 35: ...change the software language see par 3 5 5 1 Security modify the protection settings of the Wi Fi Lan cable connection see par 3 5 5 2 Calibration enter the digital compensator menu see par 3 5 5 3 To...

Page 36: ...to enable disable the network authentication When the network authentication is enabled username and password are requested by the web browser in order to prevent unauthorized access to the ZOOM300 w...

Page 37: ...or not because z axis of data depend on the z axis considered by the ZOOM300 Laser Scanner If the bubble is out of the internal smaller circle the instrument is not leveled First of all check that the...

Page 38: ...ocedure please contact the Midarex LaserTeam support Upgrade firmware Functions Follow carefully the steps to upgrade the ZOOM300 firmware Step 1 Browse your computer or server to locate the firmware...

Page 39: ...into the internal memory Tap on it to apply the change and upload the system red arrow The background color of the row containing the firmware is defined by the following criteria GRAY the firmware i...

Page 40: ...l memory Step 5 Wait until the end of the upgrade procedure It takes less than a minute to complete the process When the procedure is complete the ZOOM300 will automatically restart and the firmware w...

Page 41: ...6 1 Version It reports the identificative number of the software and hardware components of the scanner Device ID Firmware Web server System controller EDM Electronic Distance Meter BSP Board Support...

Page 42: ...e components that are working properly are marked with the initials OK If the Status is other than Ready please contact Midarex Laser Team support providing the X3K file see par 3 5 6 5 3 5 6 2 System...

Page 43: ...cs of the data for each scan mode with or without pictures capture 3 5 6 4 Features Features Functions From this menu users are allowed to easely verify which functionalities of the instrument are ena...

Page 44: ...n If required by Midarex Support download and send it via mail To download it click on Download X3K and the X3K file will be directly downloaded on the controller 3 5 6 6 Test USB dongle Test USB dong...

Page 45: ......

Reviews: