45
MAINTENANCE
Error Messages
When abnormalities occur to the machine, the workout message information
window will display “ERROR_X_Y”.
X represents the following code definitions:
Code
Explanation of code category
1
Servo motor abnormality
2
IGBT abnormality
3
Incline motor abnormality
4
Power switch abnormality
8
Communication abnormality
Y represents the sub-abnormality under the X abnormality code.
Error code explanations follow:
ERROR_1_1_ : Servo motor encoder abnormality. Restart the unit to re-
cover normal functions.
ERROR_1_2_: Servo motor excessive heat warning. The treadmill will oper-
ate at half speed.
ERROR_1_3_: Servo motor overload abnormality. Restart the unit.
ERROR_2_1_: IGBT excessive current. Restart the unit.
ERROR_2_2_: IGBT excessive heat. The treadmill will operate at half
speed.
ERROR_2_3_: Current sensor value is too high. Wait until current returns to
normal before restarting the unit.
ERROR_3_1_: Incline motor calibration abnormality.
ERROR_4_2_: Power supply voltage is too low. Wait until voltage returns to
normal before restarting the unit.
ERROR_4_3_: Power supply voltage is too high. Wait until voltage returns
to normal before restarting the unit.
ERROR_8_1_: Communication error upon start up. Resume operation when
communication is back to normal.
ERROR_8_2_: Communication abnormality. Resume operation when com-
munication is normal.
MAINTENANCE
Precautions
Turning the product on and off every day will make your software system
refresh and stable and ensure waiting 5 minutes to turn on the product
when you restart each time.
Summary of Contents for 4799.304
Page 58: ...58 Your Authorized Distributor...