92
Spohn & Burkhardt
tion.
6.1.3. Checking screw joints
Check all screw joints for correct seating.
Tighten the screws if necessary.
6.1.4. Lubricating slewing ring
Figure 43.
7.2.2
7.2.2
7.2.2
7.2.2
7.1.2
7.1.2
7.1.2
7.1.2
Lubricating slewing ring
1. Disconnect the system from the supply of electrical power.
2. Lubricate the slewing ring (
7.1
or
7.2
) via the grease nipples provided (
7.1.2
or
7.2.2
).
6.1.5. Checking cables in the slewing range
1. Disconnect the system from the supply of electrical power.
2. Open the spacer as per
section 3.2 “Electrical connection”, page 79, point 2 and 3.
3. Check the cables for damage.
Danger!
Control stands with damaged cables are not allowed to be operated.
Attention!
Make sure all cables are laid correctly without kinks or points where they can chafe.
4. Replace damaged cables.
5. Undertake setup