Date of issue:
February, 2019
Revision
1
Page
29/76
-
S
witch off the cooling system by pushing
power button B.
-
A
ctivate cleaning mode pushing the
corresponding button C.
-
R
emove the cover from the upper tank.
-
F
ill the upper tank with lukewarm water and
rinse the machine (fig.1) in order to flush it to
remove the major part of the product residuals.
-
R
epeat this operation until exiting water is
clear.
-
B
ring
K
ay-5
®
sanitizer/cleaner with a
100ppm dilution (1 Oz packet of
K
ay-5
®
+2 ½
gallons of water) (the sanitizing product shall
comply with 40 CFR §180.940).
!IMPORTANT!
T
he type and concentration of sanitizing
agent shall comply with 40 CFR §180.940
C
arefully follow the instructions of the
sanitizer manufacturer with regard to
timing and method of use.
-
T
urn off the main switch A on the right side of
the appliance and disconnect the power lead
from the mains.
-
W
ash and disinfect hands thoroughly before
performing cleaning operations otherwise use
clean and sanitized gloves.
-
F
ill the top tank with hot water (fig. 2) and
wait a few minutes.
-
E
mpty the cylinder and repeat the same
steps until the water coming out is clear (fig. 3).
Fig. 1
Fig. 2
Fig. 3