Data di emissione:
Dicembre, 2013
Revisione:
5
Pag. :
72/124
Problem
Possible cause
Solution
The touch screen display
shows
the
message
“EEPROM ERROR”
•
The main board memory is not working
•
Replace the main board
The touch screen display
shows the message “NAND
ERROR”
•
The main board images memory is not
working
•
Replace the main board
The touch screen display
shows the message “BOARD
OVERTEMPERATURE”
•
The main board temperature is too high
•
Check the root cause and solve
The touch screen display
shows
the
message
“OVERCURRENT ERROR”
•
The current absorption is too high
•
The product density or/and the
auger rotation speed are too
high, modify the functioning
parameters
The touch screen display
shows
the
message
“PRODUCT DENSITY HIGH”
•
The product consistency is too high and
the motor is not able to rotate
•
Switch the unit off, wait for the
product temperature decrease
and before operate again modify
the product temperature by
increasing it.
The touch screen display
shows
the
message
“MACHINE CODE ERROR”
•
The unit software has not been set
properly
•
Replace the main board