24
Connection of Optional Accessories
Use of any external devices not approved by the factory may cause permanent damage to the
controller and is not covered by the Spectra warranty. Accessory outputs are limited to 2
amps maximum load! Do not connect motors, pumps, etc to accessory outputs.
Ultraviolet Sterilizer:
Detailed instructions are included with the sterilizer kit. The UV steri-
lizer lamp module and ballast unit should mount vertically, with the product water inlet at the
bottom, outlet at the top. The ballast wires plug into the end of the bulb in the lamp module.
The ballast RED wire connects to “STER” terminal on the MPC board, and the ballast BLACK
wire connects to the “GND” terminal. If the wires must be extended, use minimum 16AWG
wire.
External Buzzer(s):
In addition to the external buzzer(s) installed at each remote control dis-
play panel, a buzzer unit may be installed at the control box. The buzzer RED wire connects to
the “BUZZ” terminal on the MPC board, and the buzzer BLACK wire connects to “GND.”
Optional Z-brane System:
Detailed instructions are included with the Z-Brane kit. Connect to
an uninterruptible 12 or 24 volt DC power source.