Storage Procedure:
•
Step 1: Flush the system twice. Press the “Auto Flush” button on the LCD display, once the
first flush has been completed, press “Stop” to cancel the 5 day interval timer, then press
“Auto Flush” again.
•
Step 2: Remove the quick disconnect fitting from the brine discharge outlet of the Clark
Pump, and replace with the quick disconnect hose from your service kit, and lead the hose
to a 5 gallon bucket.
•
Step 3: Press the “Auto Flush” button to fill the bucket with 1 gallon of fresh unchlorinated
water. Press “Stop” when the bucket has reached the desired level.
•
Step 4: Connect the hose, using the garden hose barb fitting from your service kit, to the ser-
vice port of the fresh water flush module. Lead the hose into the bucket. Turn the service
valve on the fresh water flush module 180°, so the intake is now coming from the bucket.
•
Step 5: Mix the storage chemical compound into the water in the bucket.
•
Step 6: Make sure the pressure relief valve on the Clark Pump is open (unpressurized).
•
Step 7: Use the “Manual” switch
on the MPC control box to
turn on the feed pump. Circulate the storage chemical in the sys-
tem for approximately 10 minutes. Turn off the pump when fin-
ished.
Clean Up:
•
Remove the quick disconnect from the Clark Pump brine discharge, and replace the original
hose that leads to the thru-hull. You may at this point, if you choose to, pump the bucket dry
by using the feed pump switch. Stop when the bucket is empty.
•
Turn the service valve 180° back to its original position, and remove the service hose.
•
Turn off the power to the system.
•
LEAVE THE PRESSURE RELIEF VALVE OPEN