Normal Start Up Using the Auto Run Button
•
Press the “Auto Run” button once and the system will prime and run for one hour. The
display reads “
Auto Run Mode
” then “
Starting
” with a 30 second priming countdown
timer. After the prime, the display reads “
Auto Run Mode
” with a countdown timer. An
hour of run time is added (up to 12 hours) with each successive momentary press of the
“Auto Run” button. An hour can be added at any time. The display shows the default
readout unless there is an alarm condition. Successive presses of the “Alarm/Display”
button will scroll through the displays starting with “
GPH Product
”. Upon auto shut
down by the timer or by the optional tank full float switches, the system will automati-
cally fresh water flush and re-flush every 5 days.
•
Pressing the “Stop” button stops the sequence at any time with no flushes.
Normal Operation
•
For optimum performance, auto run the system as long as possible at one time.
Never
let the system sit with salt water in it.
Never allow continuous air leaks in the intake.
Normal Shut Down
•
If the system was started using the “Auto Run” button, the system will shut off on its
own when the selected run time is over and will auto flush every 5 days.
•
Pressing the “Stop” button at any time will shut off the system with no auto flush func-
tion.
•
The optional tank float switches will shut off the system from any mode. If the system
was started by the “Auto Run” button, the system will flush and then re-flush every 5
days. If the system was started by the “Start/Stop” button, it will do a one-time flush. The
display will read “
Tank/s Full
”. Once one of the tank float switch opens, the alarm and
“
Tank/s Full
” display will cease on its own. Note that if “
Tank/s Full
” is displayed, the
system cannot be restarted.
If the system contains preservative or cleaning chemicals, follow the directions for “New
System Startup” or membrane damage will occur!