Chapter 15. Send Diagnostic—1Dh
53
The library does not return any data to the
SEND DIAGNOSTIC
command. If its self-test
completes successfully, the library returns a
GOOD
status. Otherwise, it returns a
CHECK
CONDITION
status. The sense information, available with a
REQUEST SENSE
command, indicates
a hardware failure (sense key 2h), and additional information may be returned in the
ASC and ASCQ.
Table 15-2: Send Diagnostic Command Field Values
Field Name
Field Location
Values
Allowed
Meaning
Byte
Bit
PF
Page Format
01
4
1
Indicates that the command parameters conform to the SCSI-2 standard.
SelfTest
01
2
1
Directs the library to perform its default self-test. This is the only
diagnostic option available through the
SEND DIAGNOSTIC
command.
DevOfL
Device off-
line
01
1
1
Permits the library to make itself unavailable while testing. The library
must be allowed to do this in order to perform the self-test.
UnitOfL
Unit off-line
01
0
1
Permits the library to take the drives off-line while performing the self-
test.
Parameter
List Length
03-04
All
00h