![Speco DVR-16TH Series User Manual Download Page 37](http://html1.mh-extra.com/html/speco/dvr-16th-series/dvr-16th-series_user-manual_1341985037.webp)
User’s Manual
DVR-4TH/8TH/16TH Series
SPECO TECHNOLOGIES 01/09
36
3.7.4
Per Camera Configuration
This function is used to set the Day/ Night/ Weekend PPS (Picture per
Second) and Quality for each channel. The Preset Configuration must be set
to <OFF> for accessing these schedules. The menu displays as follows:
(Record Mode: 352×240@120PPS in NTSC/ 352×288@100PPS in PAL).
Per Camera Config
Cameral Select
Normal PPS
Normal Qlty
Event Max PPS
Event Qlty
Event Act
Day
7.5
Best
30
Best
Both
Night
7.5
Best
30
Best
Both
CH1
Weekend
7.5
Best
30
Best
Both
•
First, select a Camera to set its record configuration. The image and
record settings from the selected camera will be displayed on the screen.
•
Move the cursor using the Direction keys and press ENTER to select an
item.
•
Change the value using UP/ DOWN keys.
•
Press ENTER to confirm the settings or ESC to abort.
•
Press ESC to return to Record Setup menu.
Please note that the total normal pps for all channels cannot exceed 120
NTSC (352×240@120PPS)/ 100 PAL (352×288@100PPS). To increase one
channel’s pps, you may have to reduce other’s first. Event pps is not
restricted to this rule, since a smart event schedule will correct the total pps
automatically..
3.7.5
Record Event Video Only
If you want your DVR unit to start recording only under the alarm is triggered,
follow the steps:
•
Enter the OSD setup menu with a proper account.
•
In the OSD setup menu, select <Record Setup> menu. Move the cursor to
the item <Preset Config>, and select <Event only>.
Refer to section
Preset Record Configuration
for more detailed information.