Faults
09|2017 EN
29
Possible cause
Solution
Pump or pipework dirty or
partly blocked.
Disassemble, clean and
check the pump and
pipework.
Replace
damaged
and/or
worn parts.
Pump is damaged.
Disassemble, clean and
check the pump.
Replace
damaged
and/or
worn parts.
Riser is damaged.
Repair
or
replace
pipework.
Problem:
Frequent stopping and starting of the pump.
Possible cause
Solution
The difference in the pressure
switch between switching on
and off is too small.
Increase the difference
(switch-off pressure may
not exceed the operating
pressure of the vessel;
switch-on pressure must
be high enough to
guarantee sufficient water
supply).
Electrodes in the water level
control or water level switch in
the container are not installed
correctly.
Set the intervals for the
electrodes so that a
reasonable amount of
time is left between
switching the pump on
and off (if there is no
automatic set up, reduce
the pump performance via
the throttle).
Non-return valve is leaky.
Repair
or
replace
non-
return valve.
Too low an air volume in the
pressure vessel/diaphragm
pressure vessel.
Pump air in (galvanised
vessel: until the air
pressure is approx. 2/3 of
the whole pressure vessel
Summary of Contents for SUPI
Page 1: ...DE Originalbetriebsanleitung EN Translation of original operation manual SUPS SUPI...
Page 3: ...DE DE Originalbetriebsanleitung SUPS SUPI...
Page 42: ......
Page 43: ...EN EN Translation of original operation manual SUPS SUPI...
Page 81: ...09 2017 39...
Page 82: ...40 09 2017...
Page 83: ...41 09 2017...