Faults
09|2017 EN
27
7 Faults
7.1 Overview
Problem:
Pump doesn’t run.
Possible cause
Solution
No voltage.
Contact the energy
supplier.
Burnt fuse
Replace the fuse; if the
problem recurs check the
electrical connection.
Motor protection triggered.
Turn
the
motor
protection
on; if the problem recurs
check the electrical
connection.
Magnetic coil in the motor
protection switch/contactor is
short circuited (does not turn
on).
Replace coil, check the
coil voltage.
Contacts in the motor
protection switch/contactor are
damaged.
Replace
motor
protection
switch/contactor.
Control current cycle failed or
is damaged.
Check the control fuse/
control current cycle and
contacts in the control
unit.
Pump is turned off due to
running dry.
Check
the
installation
height of the dry run
protection.
Check and adjust the
pressure switch settings.
Motor or cable is damaged.
Check the motor and
cable using resistance
measures.