Faults
28 EN
09|2017
Problem:
No flow rate; motor turns
Possible cause
Solution
Insufficient fluid level.
Check whether the water
level is min. 1 m above
the pump’s inlet section
during operation.
Non-return valve is blocked in
closed position.
Remove the power supply
and replace or repair the
valve.
Strainer basket is clogged.
Remove the power supply
and clean the strainer
basket in the inlet section.
Pump is damaged.
Remove the power
supply, disassemble the
pump, clean it and check
it. Replace damaged
parts.
Problem:
Too low a flow rate in the pump.
Possible cause
Solution
Incorrect direction of rotation
(3~).
Correct the direction of
rotation.
Drop in the water level is
greater than anticipated.
Check the drop during
operation and compare it
to the well and pump data.
Install the pump deeper,
reduce the drop or replace
the pump with a smaller
model.
Valves in the pressure line are
partly closed/blocked.
Maintain
the
valves.
Pressure line partly blocked
due to impurities.
Clean
or
replace
pressure
line.
Exchange
the pump for a
model with a higher
pressure head.
Pump or non-return valve
blocked.
Repair or replace valve.