Safety
10|2018 EN
11
2.7.4 Hot
surfaces
The electric motor can reach temperatures of up to 70 °C. There
is a risk of being burned.
Do not touch the motor during operation.
Allow the pump/unit to cool down before servicing it.
2.7.5 Hazardous
materials
Ensure that leaks of dangerous pumped fluids/gases are led
away without endangering people or the environment.
Decontaminate the pump completely during disassembly.
2.7.6 Suction
danger
Ensure that the suction openings conform to current guidelines,
standards and instructions.
2.8 Faults
In case of a fault, immediately switch the pump off and
remove it from operation.
Have all faults repaired immediately.
Seized pump
If a pump seizes, and is switched on several times repeatedly, the
motor can be damaged. Observe the following points:
Do not switch the pump/unit on repeatedly.
Turn the motor shaft by hand. See point 6.1.2 on page 22.
Clean
pump.
2.9 Preventing
material
damage
2.9.1 Leakage and pipe breakage
Vibrations and thermal expansion can cause pipes to break.
Install the pump/unit in a manner which reduces structure-
borne and airborne noise transmission. When doing so,
observe relevant regulations.
If the pipe forces are exceeded, leaks can occur at the screwed
connection or the pump itself.
Do not use the pump as a fixed point for the pipe line.
Connect pipes free of load and mount them elastically. Install
compensators if necessary.
If the pump leaks, the unit may not be operated and must be
disconnected from the mains power supply.
Summary of Contents for BADU Star 69/12
Page 3: ...DE DE Originalbetriebsanleitung Star Komplettfilter D41 04 009 P ...
Page 7: ...Inhaltsverzeichnis 10 2018 DE 5 10 2 Maßzeichnung 31 10 3 Kennlinie 32 11 Index 33 ...
Page 36: ......
Page 37: ...EN EN Translation of original operation manual Star Complete filter D41 04 009 P ...
Page 70: ...34 10 2018 ...