07.03.2014 TB-b bta badu jet smart_engl.indd
45
M
L
N
PE
I 30mA
FN
16A (smart and classic)
20A (super sport)
F1
K1
F2
K1
Q1
3,15A
F2
Q1
S1
2
1
6
4
5
3
2
1
96
95
A2
A1
1
3
A2
A1
=
1
Connections must be made by costumer
Residual-current device
Time-delay fuse
All-pole disconnecting switch
Contactor
Pump motor
Pressure-operated switch
Control box
Overload protection
Main
contactor
Latching
relay
The electrical connection of the unit must be made by a qualified electrician and in
observance of the DIN VDE 0100 regulations T1 and T702. The electrical equipment is
to be installed as fixed-mounted unit and outside the safety zone in a dry place (in a shaft
or at least 3.5 m away from edge of pool).
The equipment is wired ready for connection. The connections must be made in
accordance with the connection diagram.
1.
Power consumption P
1
of the pump motor is approx. 2.72 kW for three-pase AC operation
and approx. 2.27 kW for the single-phase AC pump motor.
2.
The motor protection relay is to be set to the nominal current indicated on the motor rat-
ing plate.
3.
The sense of rotation (for 3-phase AC only) must be checked during commissioning.
If the pump turns in the wrong direction, interchange phases.
4.
Connect the control tube from the pneumatic pushbutton with the one from the control
box.
Connections to be made by customer
1.
Residual-current device, I
Δ
N
= 30mA
2.
Electrical protection 1 ~ 230 V / 3 ~ 400 V with fuse 20A / 16A, time-delay, or type-K
automatic circuit breaker
3.
All-pole disconnecting switch with positions marked ‘0’ and ‘1’
4.
Equipotential bonding for connection of grounding strap must be provided.
For more information please refer to the connection diagram.
These devices are not included in the scope of supply and must be provided by the
customer before the installation of the unit.
Electrical connection for
BADU
®
Jet
smart
Single-phase AC 230V 50 Hz
Three-phase 3~ 4000 V 50 Hz
Q1
Q1
L1
N
PE
Connections must be made by costumer
Residual-current device
I 30mA
FN
Time-delay fuse 16A
All-pole disconnecting switch
Contactor
Pump motor
Pressure-operated switch
Control box
Overload protection
L2
L3
K1
F2
K1
Main
contactor
Latching
relay
F2
S1
2
1
6
4
5
3
96
95
A2
A1
1
3
A2
A1
F1
3,15A
M
3~
=
2
1
bta badu jet smart_engl.indd 45
10.03.2014 09:31:05
Summary of Contents for BADU Jet Smart KH
Page 9: ...07 03 2014 TB b bta badu jet smart indd 9 bta badu jet smart indd 9 10 03 2014 09 46 50 ...
Page 10: ...10 07 03 2014 TB b bta badu jet smart indd bta badu jet smart indd 10 10 03 2014 09 46 50 ...
Page 11: ...07 03 2014 TB b bta badu jet smart indd 11 bta badu jet smart indd 11 10 03 2014 09 46 50 ...
Page 13: ...07 03 2014 TB b bta badu jet smart indd 13 bta badu jet smart indd 13 10 03 2014 09 46 51 ...